Multiplex multidimensional nanoLC-MS system for targeted proteomic analyses
- 1 December 2005
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 26 (24) , 4575-4589
- https://doi.org/10.1002/elps.200500603
Abstract
The present work describes a dual‐column and dual‐sprayer LC‐MS system for high‐throughput proteomic analyses. This system consists of two precolumns for sample desalting and two analytical columns. Each column is terminated by a nanoelectrospray emitter mounted on a robotic arm enabling their sequential positioning in front of the sampling cone of the mass spectrometer. The effluent from each emitter is recorded in separate acquisition channels without detectable crosstalk. Gradient elution to both nanoLC columns is delivered by a single HPLC system via a flow splitter. The reproducibility of retention time and peak intensity of the present multiplex system were comparable to those obtainable using a single emitter configuration. Replicate injections of complex tryptic digests (n = 10) indicated that this system provided good reproducibility of retention time and peak intensity on both columns with RSD values of less than 0.9 and 18.6%, respectively. The application of this system is demonstrated for the monitoring of protein expression changes in U937 human monocyte cells with and without phorbol ester administration. Furthermore, we also demonstrated the use of this multiplex system in a 2‐D LC configuration to increase sample loading and throughput for the analysis of biomarker samples of higher complexity. Variations in peptide abundance down to two‐fold change were identified across salt fractions for spiked tryptic digests present at a level of 50 fmol in 1.5 μg of plasma samples.Keywords
This publication has 37 references indexed in Scilit:
- Biomarkers for melanomaCurrent Opinion in Oncology, 2005
- Current two‐dimensional electrophoresis technology for proteomicsProteomics, 2004
- Molecular biomarkers in drug developmentDrug Discovery Today, 2004
- Higher‐throughput screening for Caco‐2 permeability utilizing a multiple sprayer liquid chromatography/tandem mass spectrometry systemRapid Communications in Mass Spectrometry, 2003
- Parallel preparative high‐performance liquid chromatography with on‐line molecular mass characterizationRapid Communications in Mass Spectrometry, 2003
- Clinical biomarkers in drug discovery and developmentNature Reviews Drug Discovery, 2003
- Parallel high-throughput accurate mass measurement using a nine-channel multiplexed electrospray liquid chromatography ultraviolet time-of-flight mass spectrometry systemRapid Communications in Mass Spectrometry, 2003
- High‐speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasmaRapid Communications in Mass Spectrometry, 2002
- Increased throughput in quantitative bioanalysis using parallel‐column liquid chromatography with mass spectrometric detectionRapid Communications in Mass Spectrometry, 2001
- Induction of Differentiation in Human Promyelocytic Leukemia Cells by Tumor PromotersScience, 1979