Blood-gas and circulatory changes during total knee replacement. Role of the intramedullary alignment rod.
- 1 January 1990
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 72 (1) , 19-26
- https://doi.org/10.2106/00004623-199072010-00004
Abstract
The use of an intramedullary alignment rod in the distal part of the femur is an important step in performing total knee-replacement arthroplasty. On the basis of our observation of a sudden decrease in oxygen saturation in some patients after insertion of the rod, a prospective study was done of the circulatory and blood-gas changes that were associated with insertion in thirty-five patients. We examined the effects of the use of an eight-millimeter solid alignment rod, with and without venting; an eight-millimeter fluted alignment rod, with venting; and an eight-millimeter fluted or solid alignment rod, inserted through a 12.7-millimeter drill-hole, but without other venting. A statistically significant reduction in oxygen saturation, arterial oxygen tension (PaO2), and end-tidal carbon-dioxide tension (PETCO2) occurred after insertion of both solid and fluted eight-millimeter alignment rods through an eight-millimeter hold in both vented and unvented femoral canals, in association with a significant increase (p less than 0.01) in intramedullary pressure. Bone-marrow contents and fat were retrieved from samples of blood from the right atrium, indicating that embolization of marrow contents had occurred during insertion of the alignment rod. A small decrease in systemic blood pressure and heart rate also occurred. These changes were completely eliminated by the use of a 12.7-millimeter drill-hole as the entry site of the eight-millimeter fluted rod. We concluded that insertion of an intramedullary alignment rod in the femur causes embolization of marrow contents, which decreases arterial oxygen tension, oxygen saturation, end-tidal carbon-dioxide tension, arterial blood pressure, and heart rate.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 5 references indexed in Scilit:
- Cardiopulmonary function and pulmonary microemboli during arthroplasty using cemented or non-cemented components. The role of intramedullary pressure.Journal of Bone and Joint Surgery, 1987
- Pulmonary marrow embolism: A dog model simulating dual component cemented arthroplastyCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1987
- Effects of a distal venting hole in the femur during total hip replacementArchives of orthopaedic and trauma surgery, 1984
- The role of lavage in preventing hemodynamic and blood-gas changes during cemented arthroplasty.Journal of Bone and Joint Surgery, 1983
- Intraoperative Hemodynamic Changes during Total Knee ReplacementAnesthesiology, 1979