Statistical Evaluation of Internal and External Mass Calibration Laws Utilized in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
- 10 March 2005
- journal article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (8) , 2406-2414
- https://doi.org/10.1021/ac048258l
Abstract
The statistical evaluation of two common and three new calibration laws utilized in Fourier transform ion cyclotron resonance mass spectrometry are presented. Electrospray ionization was used to prepare a series of mass spectra of ammonium-adducted polypropylene glycol (PPG) with an average molecular weight of 1000 Da. The singly charged PPG-1000 oligomers allowed for the description of a broad range of m/z and abundance values within each mass spectrum. The hexapole accumulation time was varied to afford a range of total ion abundance values of about an order of magnitude. To examine each of the calibration laws, we utilized cross-validation both “within-spectrum” and “between-spectra” for internally and externally calibrated data, respectively. In addition, we used t-statistics to ensure that each calibration coefficient was statistically significant and necessary to accurately describe the variation in the data. In comparison to commonly used calibration laws for internal calibration, our new calibration law based on multiple linear regression offered a 2-fold improvement in mass measurement accuracy (MMA). In comparison to external calibration laws without automatic gain control, our new calibration law using multiple regression improved the MMA by >10-fold; this improvement would increase further as the dynamic range of the measurement increases (e.g., a biological system). For both our internal and external calibration laws, the median MMA was less than 1 part-per-million. Furthermore, we investigate the number of calibrant ions as well as their required m/z range in order to successfully achieve high MMA.Keywords
This publication has 29 references indexed in Scilit:
- Effect of post‐excitation radius on ion abundance, mass measurement accuracy, and isotopic distributions in Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2005
- Detection of Genetic Variants of Transthyretin by Liquid Chromatography–Dual Electrospray Ionization Fourier-Transform Ion-Cyclotron-Resonance Mass SpectrometryClinical Chemistry, 2004
- Fourier transform ion cyclotron resonance mass spectrometry: A primerMass Spectrometry Reviews, 1998
- Routine Part-per-Million Mass Accuracy for High- Mass Ions: Space-Charge Effects in MALDI FT-ICRAnalytical Chemistry, 1998
- Electron Capture Dissociation of Multiply Charged Protein Cations. A Nonergodic ProcessJournal of the American Chemical Society, 1998
- Sustained off-resonance irradiation for collision-activated dissociation involving Fourier transform mass spectrometry. Collision-activated dissociation technique that emulates infrared multiphoton dissociationAnalytica Chimica Acta, 1991
- Some Developments in Nuclear Magnetic Resonance of SolidsScience, 1989
- Space charge effects in Fourier transform mass spectrometry. II. Mass calibrationAnalytical Chemistry, 1984
- Experimental determination of the effects of space charge on ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983
- Theory of space-charge shift of ion cyclotron resonance frequenciesInternational Journal of Mass Spectrometry and Ion Processes, 1983