A TOOL TO ASSESS BIOMECHANICAL GAIT EFFICIENCY
- 1 January 1996
- journal article
- research article
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 75 (1) , 3-8
- https://doi.org/10.1097/00002060-199601000-00003
Abstract
A goal of many physiatric interventions is to improve biomechanical walking efficiency. Thus, a tool that helps assess this efficiency, independent of cardiac, pulmonary, psychologic, or other nonbiomechanical factors, would be useful. Currently used methods to measure efficiency, including comfortable walking speed, are not specific to biomechanical variables. A potential tool, the biomechanical efficiency quotient (BEQ), which uses three variables--average stride length, vertical displacement of the trunk during walking, and sacral height during standing--is proposed and preliminarily tested. This quotient is based on Saunders, Inman, and Eberhart's theories and on a prior study in able-bodied subjects. The BEQ was computed in 20 consecutive patients with neurologically based gait disability referred for gait laboratory evaluation who subjectively reported that one or two ankle-foot-orthoses (AFOs) reduced the effort necessary to walk. The quotient was calculated with and without the AFO(s) by dividing the average vertical displacement of the sacrum, which was measured with an optoelectronic system, and by a predicted displacement, which was based on the patient's sacral height and average stride length. The mean BEQ with the AFO(s) (6.3 +/- 4.4) was significantly less than the mean BEQ without the AFO(s) (9.7 +/- 7.1); P = 0.005. Furthermore, the BEQ was less with the AFO(s) compared with trials without the AFO(s) in all subjects. Percent change in BEQ with the AFO(s) (26.8 +/- 19.6) correlated with percent change in comfortable walking velocity (24.8 +/- 31.8), r = 0.73, P<0.001, across all subjects. The BEQ may be useful in specifically assessing the effect on biomechanical efficiency of physiatric interventions, despite variable nonbiomechnical factors. An instrument to measure vertical trunk displacement during walking outside of the gait laboratory would be extremely useful for further necessary longitudinal studies.Keywords
This publication has 11 references indexed in Scilit:
- MEASURED VERSUS PREDICTED VERTICAL DISPLACEMENT OF THE SACRUM DURING GAIT AS A TOOL TO MEASURE BIOMECHANICAL GAIT PERFORMANCEAmerican Journal of Physical Medicine & Rehabilitation, 1995
- Estimations of the horizontal displacement of the total body centre of mass: considerations during standing activitiesGait & Posture, 1993
- An algorithm for 3-D automatic movement detection by means of standard TV camerasIEEE Transactions on Biomedical Engineering, 1990
- Kinetic analysis of the center of gravity of the human body in normal and pathological gaitsJournal of Biomechanics, 1987
- Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal ProcessingIEEE Transactions on Biomedical Engineering, 1985
- An estimation of center of gravity from force platform dataJournal of Biomechanics, 1984
- The sources of external work in level walking and running.The Journal of Physiology, 1976
- Force platforms as ergometersJournal of Applied Physiology, 1975
- Energy Levels of Human Body Segments during Level WalkingErgonomics, 1969
- External work in walkingJournal of Applied Physiology, 1963