Exercise-Induced Coronary Artery Vasodilation Is Not Impaired by Stent Placement
- 21 May 2002
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 105 (20) , 2373-2377
- https://doi.org/10.1161/01.cir.0000016360.97819.44
Abstract
Background — Stenting has proved beneficial for treating threatened closure and reducing restenosis after balloon angioplasty. However, the implantation of a coronary metallic prosthesis has been related to impaired vasomotion distal to the stent as assessed by acetylcholine infusion. Thus, the purpose of the present study was to determine the vasomotion of stented coronary arteries and to assess its influence on the vasomotion of adjacent vessel segments during bicycle exercise. Methods and Results — Biplane quantitative coronary angiography was performed at rest and during bicycle exercise in 26 patients with coronary artery disease. Twelve patients had single vessel disease with stable angina pectoris (controls; group 1). Fourteen patients underwent coronary stenting for therapeutic reasons and were studied 10±3 months after the intervention (group 2). Minimal luminal area, stent area, and proximal and distal vessel areas were determined. In controls (group 1), vasoconstriction of the stenotic artery (− 29±4%; P P P P Conclusions — In contrast to the vasoconstriction of vessels in control patients, normal vasodilation of proximal and distal segments occurred during the physiological stress of exercise in patients with coronary stent placement. As expected, vasomotion was abolished in the stented region.Keywords
This publication has 9 references indexed in Scilit:
- Decreased Rate of Coronary Restenosis after Lowering of Plasma Homocysteine LevelsNew England Journal of Medicine, 2001
- Long-term endothelial dysfunction after coronary artery stentingJournal of the American College of Cardiology, 1999
- Abnormal Coronary Vasomotion in Hypertension: Role of Coronary Artery DiseaseJournal of the American College of Cardiology, 1996
- Three-Year Follow-up after Implantation of Metallic Coronary-Artery StentsNew England Journal of Medicine, 1996
- Prolonged proliferative response of smooth muscle cells after experimental intravascular stentingEuropean Heart Journal, 1995
- Comparison of accuracy and precision of quantitative coronary arterial analysis between cinefilm and digital systemsPublished by Springer Nature ,1994
- An overview of coronary quantitation techniques as of 1989Published by Springer Nature ,1991
- Atherosclerosis influences the vasomotor response of epicardial coronary arteries to exercise.Journal of Clinical Investigation, 1989
- Paradoxical Vasoconstriction Induced by Acetylcholine in Atherosclerotic Coronary ArteriesNew England Journal of Medicine, 1986