Effect of femoral head diameter on tissue concentration of wear debris
- 15 September 1997
- journal article
- clinical trial
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 36 (4) , 529-535
- https://doi.org/10.1002/(sici)1097-4636(19970915)36:4<529::aid-jbm11>3.0.co;2-5
Abstract
Although several studies have reported the physical properties of debris particles in tissues adjacent to failed total joint implants, few have correlated the results of particle analysis with other clinical and implant variables believed to influence implant wear. We retrospectively analyzed 41 fibrous membranes (from 35 patients) adjacent to failed acetabular cups from a single manufacturer and studied the relationship between three different femoral head sizes (26, 28, and 32 mm) and the characteristics of wear debris in the adjacent tissues. All total hip prostheses consisted of modular cobalt–chromium alloy femoral heads articulating with titanium–alloy‐backed ultrahigh molecular weight polyethylene (UHMWPE) acetabular components from a single manufacturer. Large femoral head diameter (32 mm) was found to correlate significantly with large particle size (diameter and surface area, p < 0.05), high tissue concentration of particles (particle volume/gram of tissue, p < 0.01), and high rate of particle production (particles volume/month, p < 0.05). The results of these quantitative assays support the findings of radiographically based clinical studies that show higher volumetric wear associated with 32 mm femoral head components. © 1997 John Wiley & Sons, Inc. J Biomed Mater Res, 36, 529–535, 1997.Keywords
This publication has 27 references indexed in Scilit:
- Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissuesJournal of Biomedical Materials Research, 1995
- Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prosthesesJournal of Applied Biomaterials, 1994
- Response of three murine macrophage populations to particulate debris: Bone resorption in organ culturesJournal of Orthopaedic Research, 1994
- Macrophage/particle interactions: Effect of size, composition and surface areaJournal of Biomedical Materials Research, 1994
- A method for production and characterization of metal prosthesis wear particlesJournal of Orthopaedic Research, 1993
- The Mechanism of Loosening of Cemented Acetabular Components in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992
- The effects of femoral head size on the deformation of ultrahigh molecular weight polyethylene acetabular cupsJournal of Biomechanics, 1989
- Correlation of Prosthetic Femoral Head Size and/or Design with Longevity of Total Hip ArthroplastyPublished by Wolters Kluwer Health ,1983
- Rate of Wear in Total Hip ReplacementClinical Orthopaedics and Related Research, 1975
- The Effects of Friction and Wear in Artificial JointsOrthopedic Clinics of North America, 1973