Improved determination of static compliance by automated single volume steps in ventilated patients
- 1 February 1991
- journal article
- research article
- Published by Springer Nature in Intensive Care Medicine
- Vol. 17 (2) , 108-114
- https://doi.org/10.1007/bf01691433
Abstract
A new method for determination the static compliance of the respiratory system is described (“static compliance by automated single steps”-SCASS). In 12 ventilated patients pressure/volume (P/V) curves were determined by automated repetitive occlusion (6 s) at single volume steps and compared to the conventional syringe method (SM). All measurements were corrected for effects of temperature, humidity and pressure (THP). SM was found to be significantly influenced by intrapulmonary gas exchange causing an effective mean volume deficit of 217.4±65.7 ml (BTPS) at the end of the deflation. In contrast to that, the short duration of occlusion in SCASS minimize the gas exchange effects. The methodical differences between both methods result in overestimation of the inflation compliance in the uncorrected SM (SMuncorr: 83.4±12.6; SCASS: 76.0±11.9 ml/cmH2O.puncorr: 58.3±7.5; SCASS: 79.1±15.0 ml/cmH2O.p<0.005). In contrast to the P/V curves by SM no significant hysteresis was found by SCASS. Gas exchange seems to be the main reason for the hysteresis. Even after correcting gas exchange and THP effects a significant hyseresis remained. The SCASS method avoids these problems and allows furthermore an accurate checking of leaks.Keywords
This publication has 21 references indexed in Scilit:
- Measurement of gas exchange in intensive careCritical Care Medicine, 1989
- A method for studying the static volume-pressure curves of the respiratory system during mechanical ventilationJournal of Critical Care, 1989
- Volume/pressure curve of total respiratory system in paralysed patients: artefacts and correction factorsIntensive Care Medicine, 1987
- Total respiratory compliance as a function of lung volume in patients with mechanical ventilationIntensive Care Medicine, 1985
- Total Respiratory Pressure-Volume Curves in the Adult Respiratory Distress SyndromeChest, 1984
- A new device for measurement of pulmonary pressure-volume curves in patients on mechanical ventilationCritical Care Medicine, 1983
- Clinical predictors of the adult respiratory distress syndromeThe American Journal of Surgery, 1982
- Effect of Tidal Volume and Positive End-Expiratory Pressure on Compliance during Mechanical VentilationChest, 1978
- Ventilation with end-expiratory pressure in acute lung diseaseJournal of Clinical Investigation, 1972
- Individual Comparisons by Ranking MethodsBiometrics Bulletin, 1945