Method for efficient fast spin echo Dixon imaging
Open Access
- 3 December 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (6) , 1021-1027
- https://doi.org/10.1002/mrm.10306
Abstract
In order to satisfy the Carr-Purcell-Meiboom-Gill (CPMG) condition, echo shift as dictated in fast-spin-echo (FSE)-based Dixon imaging was previously achieved by applying a time shift to the readout gradient and the data acquisition window. Accordingly, interecho spacing is increased, which entails increased image blurring and, in multislice imaging, a significant reduction in the slice coverage for a given imaging time. In this work, a new method is developed by which the echo shift is induced by “sandwiching” in time the readout gradient with a pair of small gradients of equal area and of opposite polarity. While data with non-zero phase shifts between water and fat signals are collected as fractional echoes, no increase in echo spacing is necessary with the modified acquisition strategy, and increased time efficiency is therefore achieved. In order to generate separate water-only and fat-only images in data processing, a set of low-resolution images are first reconstructed from the central symmetric portion (either 128 × 128 or 64 × 64) of the acquired multipoint Dixon data. High-resolution images using all the acquired data, including some partial Fourier-reconstructed images, are then phase demodulated using the phase errors determined from the low-resolution images. The feasibility of the technique is demonstrated using a water and fat phantom as well as in clinical patient imaging. Magn Reson Med 48:1021–1027, 2002.Keywords
This publication has 16 references indexed in Scilit:
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Separation of fat and water in fast spin‐echo MR imaging with the three‐point dixon techniqueJournal of Magnetic Resonance Imaging, 1995
- Why fat is bright in rare and fast spin‐echo imagingJournal of Magnetic Resonance Imaging, 1992
- Multipoint dixon technique for water and fat proton and susceptibility imagingJournal of Magnetic Resonance Imaging, 1991
- Homodyne detection in magnetic resonance imagingIEEE Transactions on Medical Imaging, 1991
- Comparing the FAISE method with conventional dual‐echo sequencesJournal of Magnetic Resonance Imaging, 1991
- Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correctionMagnetic Resonance in Medicine, 1991
- Improved detectability in low signal‐to‐noise ratio magnetic resonance images by means of a phase‐corrected real reconstructionMedical Physics, 1989
- RARE imaging: A fast imaging method for clinical MRMagnetic Resonance in Medicine, 1986
- Simple proton spectroscopic imaging.Radiology, 1984