Comparing the FAISE method with conventional dual‐echo sequences
- 1 May 1991
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 1 (3) , 319-326
- https://doi.org/10.1002/jmri.1880010310
Abstract
The FAISE (fast‐acquisition interleaved spin‐echo) technique consists of a hybrid rapid‐acquisition relaxation‐enhanced (RARE) sequence combined with a specific phase‐encode reordering method. Implemented on a 1.5‐T unit, this multisection, high‐resolution technique permits convenient contrast manipulation similar to that of spin‐echo imaging, with selection of a pseudo‐echo‐time parameter and a TR interval. With a TR of 2 seconds, eight 256 × 256 images are obtained in 34 seconds with either T2 or proton‐density weighting. A direct comparison between FAISE and spin echo for obtaining T2‐weighted head images in healthy subjects indicates that FAISE and spin‐echo images are qualitatively and quantitatively similar. Image artifacts are more pronounced on “proton‐density” FAISE images than on the T2‐weighted FAISE images. T1 contrast can be obtained with inversion recovery and short TR FAISE images. Preliminary temperature measurements in saline phantoms do not indicate excessive temperature increases with extended FAISE acquisitions. However, extensive studies of radio‐frequency power deposition effects should be performed if the FAISE technique is to be fully exploited.Keywords
This publication has 14 references indexed in Scilit:
- Signal loss induced by superparamagnetic iron oxide particle in NMR spin‐echo images: The role of diffusionMagnetic Resonance in Medicine, 1990
- Spin-echo attenuation by diffusion in nonuniform field gradientsJournal of Magnetic Resonance (1969), 1990
- Contrast manipulation and artifact assessment of 2D and 3D RARE sequencesMagnetic Resonance Imaging, 1990
- A computer simulation of T2 decay effects in echo planar imagingMagnetic Resonance in Medicine, 1989
- Diffusion imaging with paired CPMG sequencesMagnetic Resonance Imaging, 1988
- Variation in measured transverse relaxation in tissue resulting from spin locking with the CPMG sequenceJournal of Magnetic Resonance (1969), 1988
- Multiecho imaging sequences with low refocusing flip anglesJournal of Magnetic Resonance (1969), 1988
- Clinical applications and methodological developments of the RARE techniqueMagnetic Resonance Imaging, 1988
- A general two-site solution for the chemical exchange produced dependence of T2 upon the carr-Purcell pulse separationJournal of Magnetic Resonance (1969), 1972
- Theory of Chemical Exchange Effects in Magnetic ResonanceThe Journal of Chemical Physics, 1965