The relation between transaortic pressure difference and flow during dobutamine stress echocardiography in patients with aortic stenosis
Open Access
- 1 July 1999
- Vol. 82 (1) , 11-14
- https://doi.org/10.1136/hrt.82.1.11
Abstract
OBJECTIVE To investigate the relation between transaortic pressure difference and flow in patients with aortic stenosis. METHODS 50 asymptomatic patients with all grades of aortic stenosis were studied using dobutamine stress echocardiography. Individual plots of mean pressure drop against flow were drawn. Comparisons were made between grades of aortic stenosis as defined by the continuity equation. RESULTS A significant linear relation between pressure difference and flow was found in 34 patients (68%). There was a significant curvilinear relation in four (8%), while no significant regression line could be fitted in 12 (24%). In the 34 patients with linear fits, the slopes (mean (SD)) were 0.08 (0.07) in mild, 0.10 (0.04) in moderate, and 0.22 (0.16) in severe aortic stenosis (p = 0.0055). CONCLUSIONS Transaortic pressure difference can be related directly to flow in many patients with all grades of aortic stenosis. However, there are individual differences in slope and intercept suggesting that resistance calculated at rest may not always be representative. Raw pressure drop/flow plots may be an alternative method of describing valve function.Keywords
This publication has 16 references indexed in Scilit:
- Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. IPublished by Elsevier ,2004
- How should we manage symptomatic aortic stenosis in the patient who is 80 or older?Heart, 1995
- Flow dependence of measures of aortic stenosis severity during exerciseJournal of the American College of Cardiology, 1994
- Aortic valve resistance as an adjunct to the gorlin formula in assessing the severity of aortic stenosis in symptomatic patientsJournal of the American College of Cardiology, 1992
- Effects of dobutamine on Gorlin and continuity equation valve areas and valve resistance in valvular aortic stenosisThe American Journal of Cardiology, 1992
- When should doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow statesJournal of the American College of Cardiology, 1987
- Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography.Circulation, 1985
- Hydraulic estimation of stenotic orifice area: a correction of the Gorlin formula.Circulation, 1985
- Hemodynamic factors that affect calculated orifice areas in the mitral hancock xenograft valve.Circulation, 1980
- Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.Circulation, 1978