Ready‐made matrix‐assisted laser desorption/ionization target plates coated with thin matrix layer for automated sample deposition in high‐density array format
- 13 December 2001
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 16 (2) , 117-126
- https://doi.org/10.1002/rcm.542
Abstract
The methodology for ready‐made matrix‐assisted laser desorption/ionization (MALDI) target plates covered with an optimized thin layer consisting of matrix and nitrocellulose has been developed. Piezoelectric microdispensing enabled sample depositions in a high‐density array format of 2000 sample depositions on a conventionally sized target plate (45 × 47 mm). The sample depositions were made reproducibly in a fully automated mode by using an in‐house developed computer‐controlled piezoelectric flow‐through microdispenser. Additionally, the piezoelectric technique facilitated significant analyte enrichment that increased the detection sensitivity. The MS signal was obtained rapidly, generally within ten laser pulses. An airbrush device was used to generate a fine spray of matrix and nitrocellulose dissolved in acetone. The acetone evaporated instantly when reaching the target plate leaving the entire surface with a thin and uniform matrix/nitrocellulose coating consisting of very small crystals of matrix embedded in the nitrocellulose. These crystals acted as a seed‐layer on subsequent analyte depositions, rendering homogeneous sample spots when using α‐cyano‐4‐hydroxycinnamic acid (CHCA) as matrix. The relative standard deviation of the signal intensity between spots was (20–30)% (n = 30). The detection sensitivity was improved by restricting the sample spot diameter to 300 µm. The spot size was affected by the deposition rate and the evaporation rate of the dispensed sample volume. Mass spectra of a 25‐amol peptide mixture deposition were successfully recorded. Copyright © 2001 John Wiley & Sons, Ltd.Keywords
This publication has 25 references indexed in Scilit:
- Signal Amplification Using “Spot-on-a-Chip” Technology for the Identification of Proteins via MALDI-TOF MSAnalytical Chemistry, 2000
- Design and development of a silicon microfabricated flow-through dispenser for on-line picolitre sample handlingJournal of Micromechanics and Microengineering, 1999
- Improvement of signal reproducibility and matrix/comatrix effects in MALDI analysisAnalytical Chemistry, 1995
- Spin‐coated samples for high resolution matrix‐assisted laser desorption/ionization time‐of‐flight mass spectrometry of large proteinsRapid Communications in Mass Spectrometry, 1995
- Improved Resolution and Very High Sensitivity in MALDI TOF of Matrix Surfaces Made by Fast EvaporationAnalytical Chemistry, 1994
- A method to increase contaminant tolerance in protein matrix‐assisted laser desorption/ionization by the fabrication of thin protein‐doped polycrystalline filmsRapid Communications in Mass Spectrometry, 1994
- Use of mass spectrometric molecular weight information to identify proteins in sequence databasesJournal of Mass Spectrometry, 1993
- Sample immobilization protocols for matrix‐asssisted laser‐desorption mass spectrometryRapid Communications in Mass Spectrometry, 1992
- Laser‐induced desorption of proteinsRapid Communications in Mass Spectrometry, 1989
- Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltonsAnalytical Chemistry, 1988