Mechanical output impedance of the lung determined from cardiogenic oscillations.
- 1 August 2001
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 91 (2) , 859-865
- https://doi.org/10.1152/jappl.2001.91.2.859
Abstract
The beating heart naturally oscillates the lung because of the close juxtaposition between these organs producing cardiogenic oscillations in flow that can be measured at the mouth when the glottis is open. Correspondingly, if the mouth is occluded, the same phenomenon produces cardiogenic pressure oscillations that can be measured just distal to the site of occlusion. The Fourier-domain ratio of these oscillations in pressure and flow constitutes what we call cardiogenic respiratory impedance (Zc). We calculated Zc between about 1.5 and 10 Hz in relaxed normal subjects at functional residual capacity with open glottis. Zc was insensitive to heart rate changes induced by exercise and had an imaginary part close to zero at all frequencies investigated. Its real part was similar to or smaller than resistance determined by the forced oscillation technique. We speculate that Zc measures the flow resistance of the central and upper airways of the lung. Zc may be useful as a means of obtaining information about lung mechanics without the need for an external source of flow perturbations.Keywords
This publication has 12 references indexed in Scilit:
- Autotriggering caused by cardiogenic oscillation during flow-triggered mechanical ventilationCritical Care Medicine, 2000
- Cardiogenic Oscillations on the Airflow Signal During Continuous Positive Airway Pressure as a Marker of Central ApneaChest, 1999
- Airway closure during mixed apneas in preterm infants: Is respiratory effort necessary?The Journal of Pediatrics, 1998
- Partitioning of airway and respiratory tissue mechanical impedances by body plethysmographyJournal of Applied Physiology, 1998
- A model of the spontaneously breathing patient: applications to intrinsic PEEP and work of breathingJournal of Applied Physiology, 1997
- Use of a magnified cardiac airflow oscillation to classify neonatal apnea.American Journal of Respiratory and Critical Care Medicine, 1996
- Regional lung impedance from forced oscillations through alveolar capsulesRespiration Physiology, 1993
- Relationship between tracheal air flow and induced changes in intrathoracic volume. A basis for calibration of pneumocardiogram.Japanese Heart Journal, 1988
- Correlation of the cardiogenic air flow in the respiratory airway (i.e. the pneumocardiogram) with left ventricular stroke volume in dogs.Japanese Heart Journal, 1985
- The Dynamic Pneumocardiogram: An Application of Coherent Signal Processing to Cardiovascular MeasurementIEEE Transactions on Biomedical Engineering, 1981