The Quality of Reconstructed 3D Images in Multidetector-Row Helical CT: Experimental Study Involving Scan Parameters
Open Access
- 1 January 2002
- journal article
- Published by The Korean Society of Radiology in Korean Journal of Radiology
- Vol. 3 (1) , 49-56
- https://doi.org/10.3348/kjr.2002.3.1.49
Abstract
To determine which multidetector-row helical CT scanning technique provides the best-quality reconstructed 3D images, and to assess differences in image quality according to the levels of the scanning parameters used. Four objects with different surfaces and contours were scanned using multidetector-row helical CT at three detector-row collimations (1.25, 2.50, 5.00 mm), two pitches (3.0, 6.0), and three different degrees of overlap between the reconstructed slices (0%, 25%, 50%). Reconstructed 3D images of the resulting 72 sets of data were produced using volumetric rendering. The 72 images were graded on a scale from 1 (worst) to 5 (best) for each of four rating criteria, giving a mean score for each criterion and an overall mean score. Statistical analysis was used to assess differences in image quality according to scanning parameter levels. The mean score for each rating criterion, and the overall mean score, varied significantly according to the scanning parameter levels used. With regard to detector-row collimation and pitch, all levels of scanning parameters gave rise to significant differences, while in the degree of overlap of reconstructed slices, there were significant differences between overlap of 0% and of 50% in all levels of scanning parameters, and between overlap of 25% and of 50% in overall accuracy and overall mean score. Among the 18 scanning sequences, the highest score (4.94) was achieved with 1.25 mm detector-row collimation, 3.0 pitch, and 50% overlap between reconstructed slices. Comparison of the quality of reconstructed 3D images obtained using multidetector-row helical CT and various scanning techniques indicated that the 1.25 mm, 3.0, 50% scanning sequence was best. Quality improved as detector-row collimation decreased; as pitch was reduced from 6.0 to 3.0; and as overlap between reconstructed slices increased.Keywords
This publication has 18 references indexed in Scilit:
- Four Multidetector-Row Helical CT: Image Quality and Volume Coverage SpeedRadiology, 2000
- Multi‐slice helical CT: Scan and reconstructionMedical Physics, 1999
- Liver lesions: improved detection with dual-detector-array CT and routine 2.5-mm thin collimation.Radiology, 1998
- Algorithm for image reconstruction in multi-slice helical CTMedical Physics, 1998
- Dual‐slice spiral versus single‐slice spiral scanning: Comparison of the physical performance of two computed tomography scannersMedical Physics, 1996
- Helical CT: principles and technical considerations.RadioGraphics, 1994
- Physical performance characteristics of spiral CT scanningMedical Physics, 1991
- Three-Dimensional Volumetric Display of CT DataJournal of Computer Assisted Tomography, 1991
- Computed tomography scanning with simultaneous patient translationMedical Physics, 1990
- Spiral volumetric CT with single-breath-hold technique, continuous transport, and continuous scanner rotation.Radiology, 1990