Influence of inflammatory cells and serum on the performance of implantable glucose sensors
- 30 October 2000
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 54 (1) , 69-75
- https://doi.org/10.1002/1097-4636(200101)54:1<69::aid-jbm8>3.0.co;2-q
Abstract
The objective of this investigation was to evaluate the influence of polymorphonuclear granulocytes on the performance of uncoated and cellulose acetate/Nafion® coated amperometric glucose sensors in vitro. The response of these sensors was also investigated in serum. Uncoated and coated sensors showed lower sensitivities to glucose, with a significant drift in sensor output upon exposure to serum or leukocytes. Although the use of a coating resulted in higher sensitivity, the progressive loss of output was not completely prevented. Stimulated granulocytes were shown to excrete components, probably catalase and myeloperoxidase, which consumed the hydrogen peroxide formed by the oxidation of glucose. In addition, adsorbed serum proteins formed a diffusional barrier for glucose. Furthermore, serum was found to contain low-molecular weight components that alone inhibited glucose oxidase activity. Based on preliminary electrochemical results, we postulate that rabbit serum contains oxidizing substrates that compete with molecular oxygen for the acceptance of electrons from the oxidized enzyme. Consequently, future efforts should be aimed at elucidating the mechanisms involved in the interference of unknown serum components with electron transfer. In addition, further investigations have to be performed to develop an outer membrane that minimizes protein adsorption as well as the actions of inflammatory cells. © 2000 John Wiley & Sons, Inc.Keywords
This publication has 24 references indexed in Scilit:
- Current Status of the Glucose SensorThe Endocrinologist, 1996
- Bio‐/haemocompatibility: implications and outcomes for sensors?Acta Anaesthesiologica Scandinavica, 1995
- The function of a hydrogen peroxide-detecting electroenzymatic glucose electrode is markedly impaired in human sub-cutaneous tissue and plasmaBiosensors and Bioelectronics, 1993
- Internal membranes and laminates for adaptation of amperometric enzyme electrodes to direct biofluid analysisScandinavian Journal of Clinical and Laboratory Investigation, 1993
- Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?Journal of Biomedical Engineering, 1992
- Immune response in biocompatibilityBiomaterials, 1992
- Electropolymerized films to prevent interferences and electrode fouling in biosensorsBiosensors and Bioelectronics, 1991
- Tissue Destruction by NeutrophilsNew England Journal of Medicine, 1989
- Long-Lived Oxidants Generated by Human Neutrophils: Characterization and BioactivityScience, 1983
- Release of Inflammatory Mediators from Stimulated NeutrophilsNew England Journal of Medicine, 1980