Institutional review board approval of the study protocol and waiver of informed consent were obtained. This study was compliant with the Health Insurance Portability and Accountability Act. The purpose of this study was to retrospectively assess the scanning protocol and radiation dose associated with z-axis automatic tube current modulation in multi-detector row CT scanning of the chest. Fifty-three patients (mean age, 54 years; age range, 26-77 years; 25 men, 28 women) underwent 16-detector row chest CT with z-axis modulation and noise indexes of 10.0, 12.5, and 15.0 HU. Two radiologists independently compared images acquired with z-axis modulation and fixed tube current (180-300 mA) techniques for image noise, diagnostic acceptability, and depiction of peripheral bronchovascular markings. Tube current-time product was calculated for each study. There was good interobserver agreement between the two readers (kappa = 0.72). Compared with the fixed tube current technique, z-axis modulation provides acceptable image noise for chest CT, with an 18% and 26% reduction in tube current-time product at 10.0- and 12.5-HU noise indexes, respectively.Keywords
This publication has 17 references indexed in Scilit:
- Techniques and Applications of Automatic Tube Current Modulation for CTRadiology, 2004
- Strategies for CT Radiation Dose OptimizationRadiology, 2004
- Can Noise Reduction Filters Improve Low-Radiation-Dose Chest CT Images? Pilot StudyRadiology, 2003
- Clinical Comparison of Standard-Dose and 50% Reduced—Dose Abdominal CT: Effect on Image QualityAmerican Journal of Roentgenology, 2002
- A method to obtain the same levels of CT image noise for patients of various sizes, to minimize radiation doseThe British Journal of Radiology, 2002
- Radiation Exposure and Image Quality in Chest CT ExaminationsAmerican Journal of Roentgenology, 2001
- Radiation exposure associated with imaging of the chestCancer, 2000
- Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regionsEuropean Radiology, 2000
- Low-Dose Spiral Computed Tomography of the ThoraxInvestigative Radiology, 1998
- Niedrigdosiscomputer- tomographie des Thorax Experimentelle und klinische UntersuchungenDer Radiologe, 1996