A Monte Carlo dose calculation tool for radiotherapy treatment planning
Top Cited Papers
- 2 May 2002
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 47 (10) , 1671-1689
- https://doi.org/10.1088/0031-9155/47/10/305
Abstract
A Monte Carlo user code, MCDOSE, has been developed for radiotherapy treatment planning (RTP) dose calculations. MCDOSE is designed as a dose calculation module suitable for adaptation to host RTP systems. MCDOSE can be used for both conventional photon/electron beam calculation and intensity modulated radiotherapy (IMRT) treatment planning. MCDOSE uses a multiple-source model to reconstruct the treatment beam phase space. Based on Monte Carlo simulated or measured beam data acquired during commissioning, source-model parameters are adjusted through an automated procedure. Beam modifiers such as jaws, physical and dynamic wedges, compensators, blocks, electron cut-outs and bolus are simulated by MCDOSE together with a 3D rectilinear patient geometry model built from CT data. Dose distributions calculated using MCDOSE agreed well with those calculated by the EGS4/DOSXYZ code using different beam set-ups and beam modifiers. Heterogeneity correction factors for layered-lung or layered-bone phantoms as calculated by both codes were consistent with measured data to within 1%. The effect of energy cut-offs for particle transport was investigated. Variance reduction techniques were implemented in MCDOSE to achieve a speedup factor of 10–30 compared to DOSXYZ.Keywords
This publication has 29 references indexed in Scilit:
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- Clinical considerations of Monte Carlo for electron radiotherapy treatment planningRadiation Physics and Chemistry, 1998
- Characterization of computer simulated radiotherapy beams for Monte-Carlo treatment planningRadiation Physics and Chemistry, 1998
- A patient‐specific Monte Carlo dose‐calculation method for photon beamsMedical Physics, 1998
- Accurate characterization of Monte Carlo calculated electron beams for radiotherapyMedical Physics, 1997
- The application of correlated sampling to the computation of electron beam dose distributions in heterogeneous phantoms using the Monte Carlo methodPhysics in Medicine & Biology, 1993
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991
- Electron dose distributions in experimental phantoms: a comparison with 2D pencil beam calculationsPhysics in Medicine & Biology, 1987
- Electron beam dose distributions near standard inhomogeneitiesPhysics in Medicine & Biology, 1986
- Presta: The parameter reduced electron-step transport algorithm for electron monte carlo transportNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1986