An Unbiased Glucose Clamp Method Using a Variable Insulin Infusion: Its Application in Diabetic Adolescents
- 4 March 1990
- journal article
- Published by Wiley in Diabetic Medicine
- Vol. 7 (3) , 246-251
- https://doi.org/10.1111/j.1464-5491.1990.tb01379.x
Abstract
A simple, unbiased insulin-varying glucose clamp program is described. The aim of the program was to utilize a continuously updated array of data to predict insulin requirements for normoglycaemia. In assessing Type 1 diabetes the quantity of insulin required for maintenance of basal euglycaemia can be more clinically informative than other clamp methods. We present a method which uses an iterative computer program to predict changes in insulin infusion rate required for glucose clamping. After initial parameter estimation, the program uses no fixed algorithm but makes predictions according to previous blood glucose responses to infusion rates. The program has flexible data entry, graphic display, and running statistics including mean infusion data, mean glucose levels, and their respective standard deviations. Data for 26 consecutive overnight clamp studies have been analysed. The median coefficient of variation of glucose values at the end of the clamp was 4.1% (range 1.4-12.0%). The mean bias during the last 2 h was 0.20 +/- 0.24 mmol l-1. Cross-correlation showed that insulin had its maximal effect on the rate of decline of glucose after 15 min, and the nadir of glucose occurred 45 min after a change in insulin infusion rateKeywords
This publication has 20 references indexed in Scilit:
- Unbiased and Flexible Iterative Computer Program to Achieve Glucose ClampingDiabetes Care, 1989
- Studies on overnight insulin requirements and metabolic clearance rate of insulin in normal and diabetic man: relevance to the pathogenesis of the dawn phenomenonDiabetologia, 1986
- Practical Closed-Loop Insulin DeliveryAnnals of Internal Medicine, 1982
- A Minimal-Model-Based Glucose Clamp Yielding Insulin Sensitivity Independent of GlycemiaDiabetes, 1982
- Assessment of Insulin Resistance with the Insulin Suppression Test and the Euglycemic ClampDiabetes, 1981
- Glucose Clamping Using the Biostator GCIISHormone and Metabolic Research, 1980
- Determination of Insulin Requirements in Brittle Diabetic Patients by the Artificial PancreasDiabetes, 1978
- The development of a glucose clampMetabolism, 1975
- Insulin Disappearance after Intravenous Injection and its Effect on Blood Glucose in Diabetic and Non-Diabetic Children and AdultsClinical Science, 1972
- Plasma Insulin Responses to Oral and Intravenous Glucose: Studies in Normal and Diabetic Subjects*Journal of Clinical Investigation, 1967