Studies Made by Simulating Systole at Necropsy. VI. Estimation of Cardiac Stroke Volume From the Ballistocardiogram
- 1 November 1955
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 8 (3) , 315-329
- https://doi.org/10.1152/jappl.1955.8.3.315
Abstract
Ballistocardiograms, and estimations of central and peripheral blood pressure were secured while systole was simulated in cadavers, after first raising arterial pressure to normal or experimental levels by femoral perfusion. In 5 cadavers blood was used as perfusion fluid in 51 simulated systoles; in 14 cadavers water was used in 137 simulated systoles, conducted at both normal and abnormal levels of blood pressure. Stroke volumes estimated from ballistocardiograms were compared with known values measured in the injection syringe. The original formulae provide a reasonably good estimate of stroke volume. Tanner''s formula has a smaller standard deviation about the regression, but the absolute values estimated are too high. Improvement in estimations was sought by simple and multiple regression equations. The inclusion of a term for body surface area as a measure of size of the subject improves the estimate, the standard deviation in experiments in which blood was used falling to 8 cc. The addition of a term for age causes only slight further improvement. It is concluded that the ballistocardiogram provides a satisfactory but rather rough method of estimating stroke volume as long as the record is normal in form. It is at its best at detecting changes of stroke volume in individuals, and so should be useful in the testing of drugs and other therapeutic agents. When the ballistocardiogram is abnormal in form, estimates of stroke volume cannot be relied upon.Keywords
This publication has 15 references indexed in Scilit:
- Standardization of the Ballistocardiogram by Simulation of the Heart's Function at Necropsy; With a Clinical Method for the Estimation of Cardiac Strength and Normal Standards for ItCirculation, 1950
- Oxygen Transport, Circulation and Respiration in Healthy Subjects at Simulated Altitudes of 16,000–18,000 FeetJournal of Applied Physiology, 1948
- THE CARDIAC OUTPUT IN MAN: STUDIES WITH THE LOW FREQUENCY, CRITICALLY-DAMPED BALLISTOCARDIOGRAPH, AND THE METHOD OF RIGHT ATRIAL CATHETERIZATION 1Journal of Clinical Investigation, 1947
- THE RELATIONSHIP BETWEEN THE CARDIAC EJECTION CURVE AND THE BALLISTOCARDIOGRAPHIC FORCESAmerican Journal of Physiology-Legacy Content, 1945
- COMPARISON OF RESULTS OF THE NORMAL BALLISTOCARDIOGRAM AND A DIRECT FICK METHOD IN MEASURING THE CARDIAC OUTPUT IN MAN 1Journal of Clinical Investigation, 1942
- BALLISTOCARDIOGRAM. II. NORMAL STANDARDS, ABNORMALITIES COMMONLY FOUND IN DISEASES OF THE HEART AND CIRCULATION, AND THEIR SIGNIFICANCE 1Journal of Clinical Investigation, 1940
- STUDIES ON THE ESTIMATION OF CARDIAC OUPTUT IN MAN, AND OF ABNORMALITIES IN CARDIAC FUNCTION, FROM THE HEART'S RECOIL AND THE BLOOD'S IMPACTS; THE BALLISTOCARDIOGRAMAmerican Journal of Physiology-Legacy Content, 1939
- THE CALCULATION OF CARDIAC OUTPUT AND EFFECTIVE PERIPHERAL RESISTANCE FROM BLOOD PRESSURE MEASUREMENTS WITH AN APPENDIX ON THE SIZE OF THE AORTA IN MANAmerican Journal of Physiology-Legacy Content, 1935
- Die Rückstoßkurve des Herzens (Kardiodynamogramm)1Skandinavisches Archiv Für Physiologie, 1933
- AN IMPROVED METHOD FOR THE DETERMINATION OF CARDIAC OUTPUT IN MAN BY MEANS OF ETHYL IODIDEAmerican Journal of Physiology-Legacy Content, 1928