Epithelial, Stromal, and Total Corneal Thickness in Keratoconus: Three-dimensional Display With Artemis Very-high Frequency Digital Ultrasound
Top Cited Papers
- 1 April 2010
- journal article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 26 (4) , 259-271
- https://doi.org/10.3928/1081597x-20100218-01
Abstract
PURPOSE: To characterize the epithelial, stromal, and total corneal thickness profile in a population of eyes with keratoconus. METHODS: Epithelial, stromal, and total corneal thickness profiles were measured in vivo by Artemis very high-frequency (VHF) digital ultrasound scanning (ArcScan) across the central 6- to 10-mm diameter of the cornea on 54 keratoconic eyes. Maps of the average, standard deviation, minimum, maximum, and range of epithelial, stromal, and total corneal thickness were plotted. The average location of the thinnest epithelium, stroma, and total cornea were found. The cross-sectional semi-meridional stromal and total corneal thickness profiles were calculated using annular averaging. The absolute stromal and total corneal thickness progressions relative to the thinnest point were calculated using annular averaging as well as for 8 semi-meridians individually. RESULTS: The mean corneal vertex epithelial, stromal, and total corneal thicknesses were 45.7±5.9 µm, 426.4±38.5 µm, and 472.2±41.4 µm, respectively. The average epithelial thickness profile showed an epithelial doughnut pattern characterized by localized central thinning surrounded by an annulus of thick epithelium. The thinnest epithelium, stroma, and total cornea were displaced on average by 0.48±0.66 mm temporally and 0.32±0.67 mm inferiorly, 0.31±0.45 mm temporally and 0.54±0.37 mm inferiorly, and 0.31±0.43 mm temporally and 0.50±0.35 mm inferiorly, respectively, with reference to the corneal vertex. The increase in semi-meridional absolute stromal and total corneal thickness progressions was greatest inferiorly and lowest temporally. CONCLUSIONS: Three-dimensional thickness mapping of the epithelial, stromal, and total corneal thickness profiles characterized thickness changes associated with keratoconus and may help in early diagnosis of keratoconus. [ J Refract Surg . 2010;26:259–271.]Keywords
This publication has 36 references indexed in Scilit:
- Stromal Thickness in the Normal Cornea: Three-dimensional Display With Artemis Very High-Frequency Digital UltrasoundJournal of Refractive Surgery, 2009
- Repeatability and Reproducibility of Pachymetric Mapping with Visante Anterior Segment–Optical Coherence TomographyInvestigative Opthalmology & Visual Science, 2007
- Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam systemJournal of Cataract & Refractive Surgery, 2007
- Combined Artemis very high-frequency digital ultrasound-assisted transepithelial phototherapeutic keratectomy and wavefront-guided treatment following multiple corneal refractive proceduresJournal of Cataract & Refractive Surgery, 2006
- Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconusJournal of Cataract & Refractive Surgery, 2006
- Artemis very high-frequency digital ultrasound-guided repositioning of a free cap after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2006
- Progressão da espessura corneana do ponto mais fino em direção ao limbo: estudo de uma população normal e de portadores de ceratocone para criação de valores de referênciaArquivos Brasileiros de Oftalmologia, 2006
- An evaluation of the keratoconic cornea using computerised corneal mapping and ultrasonic measurements of corneal thicknessOphthalmic and Physiological Optics, 1996
- An evaluation of the keratoconic cornea using computerised corneal mapping and ultrasonic measurements of corneal thicknessOphthalmic and Physiological Optics, 1996
- Histopathological Variation in KeratoconusCornea, 1992