CT and MR Imaging of the Liver Using Liver-Specific Contrast Media
- 1 January 1996
- journal article
- research article
- Published by SAGE Publications in Acta Radiologica
- Vol. 37 (1P1) , 242-249
- https://doi.org/10.1177/02841851960371p155
Abstract
Purpose: A new type of liposomal liver-specific contrast medium (CM) in CT was studied, and the results were compared with those obtained with Mn-DPDP, a paramagnetic hepatobiliary CM, in MR imaging. The contrasts of normal liver tissue to tumorous tissue and the importance of the CM for tumour detection in the 2 modalities were studied in a rabbit tumour model. CT and T1-weighted pre- and postcontrast and T2-weighted MR images precontrast were obtained. Material, Methods and Results: Compared to precontrast images, significantly higher contrasts of normal liver tissue to tumorous tissue were obtained after CM administration in both CT and MR examinations. At radiologic evaluation, significantly more tumours were detected after CM administration in CT and in T1-weighted MR images than in precontrast images in CT and T1-weighted MR. There were no significant differences in tumour detection frequency in MR studies including a T2-weighted pulse sequence, postcontrast CT, or postcontrast T1-weighted MR imaging. Conclusion: The use of liver-specific CM improves visualization of liver tumours in CT and T1-weighted MR imaging.Keywords
This publication has 32 references indexed in Scilit:
- Imaging of patients with potentially resectable hepatic neoplasms.American Journal of Roentgenology, 1992
- Hepatic MR imaging with Mn-DPDP: safety, image quality, and sensitivity.Radiology, 1992
- Focal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.Radiology, 1992
- Matchmaking and McNemar in the comparison of diagnostic modalities.Radiology, 1991
- Preclinical evaluation of MnDPDP: new paramagnetic hepatobiliary contrast agent for MR imaging.Radiology, 1991
- Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years.American Journal of Roentgenology, 1990
- Production and Characterization of Improved Liposomes Containing Radiographic Contrast MediaInvestigative Radiology, 1990
- Magnetic Starch Microspheres, Biodistribution and BiotransformationInvestigative Radiology, 1990
- Magnetic Starch Microspheres, Efficacy and Elimination A New Organ-Specific Contrast Agent for Magnetic Resonance ImagingInvestigative Radiology, 1990
- Conventional and rapid MR imaging of the liver with Gd-DTPA.Radiology, 1987