Measurement of blood volume using indocyanine green measured with pulse-spectrophotometry
- 1 August 1998
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 26 (8) , 1446-1451
- https://doi.org/10.1097/00003246-199808000-00036
Abstract
To systematically investigate the reproducibility and reliability of a newly developed, less invasive approach of estimating blood volume (BV), using indocyanine green (ICG) measured with pulse-spectrophotometry. Prospective, clinical study. Surgical unit at a university hospital. Twenty-two patients undergoing general anesthesia for elective surgery and seven healthy volunteers. Catheters were inserted into the forearm veins of healthy volunteers for the administration of ICG and blood sampling for the measurement of hemoglobin concentration. The distribution volumes of ICG in seven healthy volunteers were estimated repetitively following three or four consecutive intravenous administrations at 30-min intervals. A low intrasubject coefficient of variation of 3.94 +/- 2.03 (SEM) % and a reasonable intersubject coefficient of variation of 13.3 +/- 5.52% (in mL/kg) for the BV measurements were obtained. In addition, ICG was administered to 22 patients, first under general anesthesia by a bolus, and then by a bolus with a constant-rate infusion. The ICG blood concentration was noninvasively measured with pulse-spectrophotometry. The blood concentration time courses following both bolus and constant-rate infusion were well fitted by the one-compartment model, indicating that the distribution equilibrium of ICG is instantaneous. The distribution volumes estimated following bolus injection correlate closely with the distribution volume estimated based on constant-rate infusion administration (r2 = .90). The BV estimation with a bolus injection of ICG and pulse-spectrophotometry is reliable, as reflected by the reproducible BVs estimated in the same subject. The integrated pulse-spectrophotometry monitoring system offers a less invasive and useful tool for bedside estimation of BV.Keywords
This publication has 16 references indexed in Scilit:
- Accuracy and reproducibility of the measurement of actively circulating blood volume with an integrated fiberoptic monitoring systemCritical Care Medicine, 1995
- A method for measurement of total circulating blood volume using indocyanine green.The Tohoku Journal of Experimental Medicine, 1986
- Reliability of clinical monitoring to assess blood volume in critically ill patientsCritical Care Medicine, 1984
- Determination of blood volume using indocyanine green (Cardio-Green®) dyeLife Sciences, 1968
- INDOCYANINE GREEN: OBSERVATIONS ON ITS PHYSICAL PROPERTIES, PLASMA DECAY, AND HEPATIC EXTRACTION*Journal of Clinical Investigation, 1960
- Determination of Circulating Red Cell Volume by Radioactive ChromiumScience, 1950
- TRAUMATIC SHOCK: IV. A STUDY OF THE PROBLEM OF THE “LOST PLASMA” IN HEMORRHAGIC SHOCK BY THE USE OF RADIOACTIVE PLASMA PROTEINJournal of Clinical Investigation, 1943
- A Method of Blood Volume DeterminationActa Physiologica Scandinavica, 1940
- CLINICAL STUDIES OF THE BLOOD VOLUME. I. CLINICAL APPLICATION OF A METHOD EMPLOYING THE AZO DYE “EVANS BLUE” AND THE SPECTROPHOTOMETERJournal of Clinical Investigation, 1937
- A METHOD FOR THE DETERMINATION OF PLASMA AND BLOOD VOLUMEArchives of internal medicine (1960), 1915