In vivo recovery with products of very high purity — assay discrepancies
- 1 July 1998
- journal article
- research article
- Published by Wiley in Haemophilia
- Vol. 4 (4) , 641-645
- https://doi.org/10.1046/j.1365-2516.1998.440641.x
Abstract
Summary. In view of reports of FVIII assay discrepancies in post‐infusion plasma samples depending on methods used, we compared FVIII results run by each of four different methods following infusion of rFVIII (Kogenate®). Nine persons with haemophilia A were infused with each of two lots of product. Plasma samples were obtained at baseline, and at 10 min, 30 min, 1, 2, 4, 8, 12, 14, 30 and 48 h post‐infusion for measurement of FVIII. FVIII assay methods were chromogenic, and one‐stage APTT using three different types of activators: micronized, silica, ellagic acid, and kaolin. The same reference plasma standard was used throughout. Results demonstrated a consistent difference in FVIII values, with chromogenic assays being considerably higher than those run by one‐stage assays. The discrepancy was greatest when kaolin was the activator. These results point out the problems in attempting to determine the “correct” FVIII level in patient plasma samples following infusion of high purity FVIII preparations. Potential “pitfalls” include the standard used for defining product potency, the methods, reagents, instrumentation and standards used in assaying plasma samples and, in some instances, the characteristics of the product itself. This situation has considerable cost implications, potential impact on patient care, and makes it difficult to compare results between laboratories.Keywords
This publication has 19 references indexed in Scilit:
- Improved cost‐effectiveness by pharmacokinetic dosing of factor VIII in prophylactic treatment of haemophilia AHaemophilia, 1997
- The pharmacokinetics of factor VIII and factor IX: methodology, pitfalls and applicationsHaemophilia, 1997
- Standardization and AssaySeminars in Thrombosis and Hemostasis, 1993
- On the unreliability of one-stage factor VIII:C clotting assays after infusion of factor VIII concentratesScandinavian Journal of Clinical and Laboratory Investigation, 1987
- Factor VIII Concentrates: Matching What You See With What You GetPublished by American Medical Association (AMA) ,1985
- Assay of Factor VIII:C with a Chromogenic SubstrateScandinavian Journal of Haematology, 1984
- North American Study of Factor VIII Concentrate PotencyScandinavian Journal of Haematology, 1984
- Calculations of Factor VIII in vivo Recovery and Half‐lifeScandinavian Journal of Haematology, 1984
- ONE OR TWO STAGE ASSAY FOR FACTOR VIII?The Lancet, 1979
- The Assay of Antihaemophilic-Globulin ActivityBritish Journal of Haematology, 1955