Multicycle Mechanical Performance of Titanium and Stainless Steel Transpedicular Spine Implants
- 1 April 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Spine
- Vol. 23 (7) , 782-788
- https://doi.org/10.1097/00007632-199804010-00008
Abstract
This was a prospective in vitro study comparing titanium alloy and stainless steel alloy in transpedicular spine implants from two different manufacturers. To compare the multicycle mechanical performance of these two alloys, used in each of two different implant designs. Transpedicular spine implants primarily have been manufactured from stainless steel, but titanium alloy offers imaging advantages. However, the notch sensitivity of titanium alloy has caused concern regarding how implants made from this material will compare in stiffness and fatigue life with implants made from stainless steel. Twenty-four implants (two alloys, two designs, six implants per group) were mounted in machined polyethylene wafers and repetitively loaded (up to 1 million cycles) from 80 N to 800 N using a 5-Hertz sinusoidal waveform. Load and displacement data were automatically and periodically sampled throughout the entire test. Implant stiffness increased with cycle load number, reached a steady state, then declined just before fatigue failure. Stiffness varied less in titanium transpedicular spine implants than in their stainless counterparts. All stainless steel implant types were stiffer (steady-state value, P < 0.0001) than their titanium alloy counterparts. One titanium implant design failed with fewer (P < 0.05) load cycles than its stainless steel counterpart, whereas a stainless steel implant of another design failed with fewer (P = 0.002) load cycles than its titanium counterpart. Overall, fatigue life, i.e., the total number of load cycles until failure, was related to implant type (P < 0.0001), but not to implant material. A transpedicular spine implant's fatigue lifetime depends on both the design and the material and cannot be judged on material alone. Stainless steel implants are stiffer than titanium alloy implants of equal design and size; however, for those designs in which the fatigue life of the titanium alloy version is superior, enlargement of the implant's components can compensate for titanium's lower modulus of elasticity and result in an implant equally stiff as its stainless steel counterpart. Such an implant made from titanium alloy would then be clinically preferable because of titanium's previously reported imaging advantages.Keywords
This publication has 15 references indexed in Scilit:
- Effect of Spinal Construct Stiffness on Short Segment Fusion Mass IncorporationSpine, 1995
- Controversy Biomechanical Testing of the SpineSpine, 1995
- Magnetic Resonance Imaging of Titanium Anterior Cervical Spine Plating SystemsNeurosurgery, 1995
- Static and Cyclical Biomechanical Analysis of Pedicle Screw Spinal ConstructsSpine, 1993
- A Prospective, Randomized Study of Lumbar FusionSpine, 1993
- The Effect of Spinal Implant Rigidity on Vertebral Bone Density A Canine ModeSpine, 1991
- Biomechanics of Thoracolumbar Spinal FixationSpine, 1991
- Anterior and Posterior Cervical Spine Fixation Using Titanium Implants to Facilitate Magnetic Resonance Imaging EvaluationJournal of Orthopaedic Trauma, 1989
- Titanium Wire Internal Fixation for Stabilization of Injury of the Cervical Spine: Clinical Results and Postoperative Magnetic Resonance Imaging of the Spinal CordNeurosurgery, 1989
- A Biomechanical Study of Intrapeduncular Screw Fixation in the Lumbosacral SpineClinical Orthopaedics and Related Research, 1986