Image Quality of Noninvasive Coronary Angiography Using Multislice Spiral Computed Tomography and Electron-beam Computed Tomography
- 1 June 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 39 (6) , 357-364
- https://doi.org/10.1097/01.rli.0000123316.10765.6c
Abstract
Comparison of coronary artery visualization by multislice spiral CT (MSCT) and electron-beam CT (EBCT). Six minipigs underwent MSCT (collimation 4 x 1 mm, gantry rotation time 500 milliseconds, acquisition time per cardiac cycle 126 +/- 30 milliseconds) and EBCT (slice thickness 1.5 mm, acquisition time per scan 100 milliseconds). Visualized vessel length and contour sharpness was measured, contrast-to-noise ratios were calculated, and the frequency of motion artifacts were evaluated. MSCT depicted significantly longer segments of the coronary tree than EBCT (length: 248.8 vs. 222.8 mm; P < 0.05), delineated the vessel contours more sharply (slope of density curves: 219.2 vs. 160.2 DeltaHU/mm; P < 0.05), and had a higher contrast-to-noise ratio (13.4 vs. 7.3; P < 0.05). The frequency of motion artifacts did not differ between both modalities (94.7% vs. 95.7% of visualized vessel length; P > 0.05). Because its higher spatial resolution and lower image noise, MSCT seems to be superior to EBCT in the visualization of the coronary arteries. Despite different temporal resolutions motion artifacts seem to be similar with both modalities.Keywords
This publication has 25 references indexed in Scilit:
- Non-invasive intravenous coronary angiography using electron beam tomography and multislice computed tomographyHeart, 2003
- Comparison of Image Quality in Contrast-enhanced Coronary-artery Visualization by Electron Beam Tomography and Retrospectively Electrocardiogram-gated Multislice Spiral Computed TomographyInvestigative Radiology, 2003
- Image Quality in a Standardized Algorithm for Minimally Invasive Coronary Angiography with Multislice Spiral Computed TomographyJournal of Computer Assisted Tomography, 2003
- Radiation Exposure during Cardiac CT: Effective Doses at Multi–Detector Row CT and Electron-Beam CTRadiology, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- Noninvasive Coronary Angiography Using Computed TomographyCirculation, 2002
- Noninvasive Visualization of Coronary Arteries Using Contrast-Enhanced Multidetector CT: Influence of Heart Rate on Image Quality and Stenosis DetectionAmerican Journal of Roentgenology, 2002
- Detection of Coronary Artery Stenoses With Multislice Helical CT AngiographyJournal of Computer Assisted Tomography, 2002
- Techniques for the Detection of Coronary Atherosclerosis: Multi–detector Row CT Coronary AngiographyRadiology, 2002
- Coronary Arteries: Retrospectively ECG-gated Multi–Detector Row CT Angiography with Selective Optimization of the Image Reconstruction WindowRadiology, 2001