Abstract
To measure the effective radiation doses delivered at electron-beam computed tomography (CT) and multi-detector row spiral CT of coronary arteries and to compare these doses with those delivered at catheter coronary angiography. An anthropomorphic phantom equipped with 66 thermoluminescent dosimeters was imaged at cardiac CT. Four protocols for unenhanced coronary artery calcium scoring were simulated: one with electron-beam CT and three with multi-detector row CT. Four similar protocols for coronary CT angiography were simulated. All multi-detector row spiral CT protocols were performed with retrospective electrocardiographic triggering. Biplane catheter coronary angiography also was simulated. Radiation doses to organs were measured, and effective doses were calculated according to guidelines published in International Commission on Radiological Protection Publication 60. Coronary artery calcium scoring with electron-beam CT yielded effective radiation doses of 1.0 and 1.3 mSv for male and female patients, respectively. The radiation doses at calcium scoring with multi-detector row CT were 1.5-5.2 mSv for male patients and 1.8-6.2 mSv for female patients. Electron-beam CT coronary angiography yielded effective doses of 1.5 and 2.0 mSv for male and female patients, respectively. The highest effective doses were delivered at multi-detector row CT angiography: 6.7-10.9 mSv for male patients and 8.1-13.0 mSv for female patients. Catheter coronary angiography yielded effective doses of 2.1 and 2.5 mSv for male and female patients, respectively. Higher radiation doses are delivered at multi-detector row cardiac CT compared with the doses delivered at electron-beam CT and catheter coronary angiography.Keywords
This publication has 47 references indexed in Scilit:
- Noninvasive detection of coronary lesions by multislice computed tomography: Results of the new age pilot trialCatheterization and Cardiovascular Interventions, 2001
- Acute pressure overload cardiac arrhythmias are dependent on the presence of myocardial tissue catecholaminesHeart, 2001
- Radiation Exposure in Multi-Slice CT of the HeartRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2001
- Multidetector CT des Herzens: Erste Klinische Anwendung einer retrospektiv EKG-gesteuerten Spirale mit optimierter zeitlicher und örtlicher Auflösung zur Darstellung der HerzkranzgefäßeRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2000
- ECG-correlated imaging of the heart with subsecond multislice spiral CTIEEE Transactions on Medical Imaging, 2000
- Early Lung Cancer Action Project: overall design and findings from baseline screeningThe Lancet, 1999
- Effective doses for coronary angiographyThe British Journal of Radiology, 1996
- IntroductionThe American Journal of Cardiology, 1991
- Detection of calcific deposits in coronary arteries by ultrafast computed tomography and correlation with angiographyThe American Journal of Cardiology, 1989
- Coronary arteriography and coronary artery bypass surgery: morbidity and mortality in patients ages 65 years or older. A report from the Coronary Artery Surgery Study.Circulation, 1983