Sugar additives for MALDI matrices improve signal allowing the smallest nucleotide change (A:T) in a DNA sequence to be resolved
- 1 October 2001
- journal article
- research article
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 29 (19) , e91
- https://doi.org/10.1093/nar/29.19.e91
Abstract
Sample preparation for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) of DNA is critical for obtaining high quality mass spectra. Sample impurity, solvent content, substrate surface and environmental conditions (temperature and humidity) all affect the rate of matrix-analyte co-crystallization. As a result, laser fluence threshold for desorption/ionization varies from spot to spot. When using 3-hydroxypicolinic acid (3-HPA) as the matrix, laser fluence higher than the threshold value reduces mass resolution in time-of-flight (TOF) MS as the excess energy transferred to DNA causes metastable decay. This can be overcome by either searching for 'hot' spots or adjusting the laser fluence. However, both solutions may require a significant amount of operator manipulation and are not ideal for automatic measurements. We have added various sugars for crystallization with the matrix to minimize the transfer of excess laser energy to DNA molecules. Fructose and fucose were found to be the most effective matrix additives. Using these additives, mass resolution for DNA molecules does not show noticeable deterioration as laser energy increases. Improved sample preparation is important for the detection of single nucleotide polymorphisms (SNPs) using primer extension with a single nucleotide. During automatic data acquisition it is difficult to routinely detect heterozygous A/T mutations, which requires resolving a mass difference of 9 Da, unless a sugar is added during crystallization.Keywords
This publication has 44 references indexed in Scilit:
- Sequencing exons 5 to 8 of the p53 gene by MALDI-TOF mass spectrometryNature Biotechnology, 1998
- Oligonucleotide Sequencing by Fragmentation in Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass SpectrometryRapid Communications in Mass Spectrometry, 1997
- Controlling DNA Fragmentation in MALDI-MS by Chemical ModificationAnalytical Chemistry, 1997
- High-Resolution MALDI Fourier Transform Mass Spectrometry of OligonucleotidesAnalytical Chemistry, 1996
- The Study of 2,3,4-Trihydroxyacetophenone and 2,4,6-Trihydroxyacetophenone as Matrices for DNA Detection in Matrix-assisted Laser Desorption/Ionization Time-of-flight Mass SpectrometryRapid Communications in Mass Spectrometry, 1996
- Applications of Delayed Extraction Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry to Oligonucleotide AnalysisAnalytical Chemistry, 1996
- Improvement of signal reproducibility and matrix/comatrix effects in MALDI analysisAnalytical Chemistry, 1995
- Procedures for detection of DNA by matrix‐assisted laser desorption/ionization mass spectrometry using a modified nafion film substrateRapid Communications in Mass Spectrometry, 1995
- High-resolution matrix-assisted laser desorption/ionization of biomolecules by Fourier transform mass spectrometryJournal of the American Chemical Society, 1992
- Instrumentation, applications, and energy deposition in quadrupole ion-trap tandem mass spectrometryAnalytical Chemistry, 1987