Comparison of ATB Staph, Rapid ATB Staph, Vitek, and E-Test Methods for Detection of Oxacillin Heteroresistance in Staphylococci Possessing mecA
- 1 January 1998
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 36 (1) , 52-57
- https://doi.org/10.1128/jcm.36.1.52-57.1998
Abstract
The performance characteristics of the E-test (AB Biodisk, Solna, Sweden), the ATB Staph, the Rapid ATB Staph, and the Vitek GPS-503 card (bioMérieux, La Balme Les Grottes, France) methods for the detection of oxacillin resistance in a collection of staphylococci with a high proportion of troublesome strains were evaluated. Sixty-four Staphylococcus aureus strains and 76 coagulase-negative staphylococcal strains were tested. All strains were mecA positive and were characterized by the oxacillin agar screen plate test; 75 (53.6%) were found to be heterogeneous by a large-inoculum oxacillin disk diffusion assay, and oxacillin MICs for 89 (63.6%) were ≤32 μg/ml. Three (4.7%) S. aureus strains and 25 (32.9%) coagulase-negative strains were classified as susceptible by the E-test, as defined by the National Committee for Clinical Laboratory Standards (NCCLS) oxacillin breakpoint (MIC ≤ 2 μg/ml). The ATB Staph method failed to detect oxacillin resistance in 7 (11%) S. aureus isolates and 32 (42.1%) coagulase-negative isolates. The MICs for all but six of these discrepant isolates were ≤16 μg/ml. The Rapid ATB Staph method was tested against S. aureus strains only and yielded 15 (23.4%) false-susceptible results for strains for which the MICs were ≤32 μg/ml. The Vitek system was the best-performing system, since it failed to detect oxacillin resistance in only 3 (4.7%) S. aureus strains and 15 (19.7%) coagulase-negative strains, the MICs for all of which were ≤2 μg/ml. These data indicate that (i) the performance of the two ATB Staph systems can be limited when the prevalence of borderline-heteroresistant staphylococci is high and (ii) the unreliability of the E-test and the Vitek methods for detecting resistant coagulase-negative strains might be reduced by the potential revision of the oxacillin breakpoint currently recommended by the NCCLS.Keywords
This publication has 35 references indexed in Scilit:
- European multicentre evaluation of a commercial system for identification of methicillin-resistantStaphylococcus aureusEuropean Journal of Clinical Microbiology & Infectious Diseases, 1996
- Impact ofsarandagron methicillin resistance inStaphylococcus aureusFEMS Microbiology Letters, 1996
- Choice of a routine method for detecting methicillin-resistance in staphylococciJournal of Antimicrobial Chemotherapy, 1996
- Detection of the mec-A gene and phenotypic detection of resistance in Staphylococcus aureus isolates with borderline or low-level methicillin resistanceJournal of Antimicrobial Chemotherapy, 1996
- Revised interpretation of oxacillin MICs for Staphylococcus epidermidis based on mecA detectionAntimicrobial Agents and Chemotherapy, 1995
- Reassessment of the number of auxiliary genes essential for expression of high-level methicillin resistance in Staphylococcus aureusAntimicrobial Agents and Chemotherapy, 1994
- Comparison of tests for detection of methicillin-resistant Staphylococcus aureus in a clinical microbiology laboratoryAntimicrobial Agents and Chemotherapy, 1994
- Comparison of a polymerase chain reaction assay and a conventional microbiologic method for detection of methicillin-resistant Staphylococcus aureusAntimicrobial Agents and Chemotherapy, 1992
- Correlation between regulation of mecA transcription and expression of methicillin resistance in staphylococciAntimicrobial Agents and Chemotherapy, 1992
- Methicillin-resistant staphylococci: detection methods and treatment of infectionsAntimicrobial Agents and Chemotherapy, 1989