Revised interpretation of oxacillin MICs for Staphylococcus epidermidis based on mecA detection

Abstract
In 1992 and 1993, at The Ohio State University Medical Center, a larger proportion of Staphylococcus epidermidis strains required oxacillin MICs of 1 to 2 micrograms/ml than did Staphylococcus aureus strains. mecA genotype was correlated with antimicrobial susceptibility for selected clinical S. epidermidis strains. All 14 strains that required oxacillin MICs of < or = 0.25 microgram/ml and 2 of 5 strains that required oxacillin MICs of 0.5 microgram/ml were susceptible by 1-microgram oxacillin disk test and were mecA negative. Three of 5 strains that required oxacillin MICs of 0.5 microgram/ml and all 18 strains that required oxacillin MICs of > or = 1.0 microgram/ml were resistant by oxacillin disk test and were mecA positive. Current National Committee for Clinical Laboratory Standards MIC interpretive criteria may underestimate methicillin resistance among S. epidermidis strains.

This publication has 13 references indexed in Scilit: