Mechanisms of Ventricular Fibrillation in Canine Models of Congestive Heart Failure and Ischemia Assessed by In Vivo Noncontact Mapping
- 13 September 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 112 (11) , 1532-1541
- https://doi.org/10.1161/circulationaha.104.521351
Abstract
Background— Much of the research performed studying the mechanism of ventricular fibrillation (VF) has been in normal ventricles rather than under a pathological condition predisposing to VF. We hypothesized that different ventricular substrates would alter the mechanism and characteristics of VF. Methods and Results— Three groups of dogs were studied: (1) control (n=8), (2) pacing-induced congestive heart failure (n=7), and (3) acute ischemia produced by 30 minutes of mid left anterior descending artery ligation (n=5). A noncontact mapping catheter (Ensite 3000, ESI) was placed via transseptal into the left ventricle (LV), along with an electrophysiology catheter. A multielectrode basket catheter (EP Technologies) was placed in the right ventricle, along with an electrophysiology catheter. Several episodes of VF were recorded in each animal. In addition to constructing isopotential and isochronal maps of the VF episodes, signals underwent frequency domain analysis as a fast Fourier transform was performed over a 2-second window every 1 second. From the fast Fourier transform, the dominant frequency was determined, and the organization was calculated. In control dogs, meandering, reentrant spiral wave activity was the main feature of the VF. The congestive heart failure group showed evidence of a stable rotor (n=3), evidence of a focal source (n=3), or no evidence of a driver in the LV (n=1). The ischemic group showed evidence of an initial focal mechanism that transitioned into reentry. In the control and ischemic groups, the LV always had higher dominant frequencies than the right ventricle. Conclusions— Different ventricular substrates produced by the different animal models altered the characteristics of VF. Thus, different mechanisms of VF may be present in the LV, depending on the animal model.Keywords
This publication has 45 references indexed in Scilit:
- Effect of remodelling, stretch and ischaemia on ventricular fibrillation frequency and dynamics in a heart failure modelCardiovascular Research, 2005
- Coexistence of Two Types of Ventricular Fibrillation During Acute Regional Ischemia in Rabbit VentricleJournal of Cardiovascular Electrophysiology, 2004
- Mother Rotors and the Mechanisms of D600-Induced Type 2 Ventricular FibrillationCirculation, 2004
- Determination of Human Ventricular Repolarization by Noncontact MappingCirculation, 2004
- Radiofrequency Ablation of Idiopathic Ventricular Fibrillation Guided by Noncontact MappingJournal of Cardiovascular Electrophysiology, 2004
- Sustained Reentry in the Left Ventricle of Fibrillating Pig HeartsCirculation Research, 2003
- Two Types of Ventricular Fibrillation in Isolated Rabbit HeartsCirculation, 2002
- Frequency Analysis of Ventricular Fibrillation in Swine VentriclesCirculation Research, 2002
- Dynamics of Intramural Scroll Waves in Three-dimensional Continuous Myocardium with Rotational AnisotropyJournal of Theoretical Biology, 1999
- A computer model of atrial fibrillationPublished by Elsevier ,1964