Computed Tomography Colonography
- 1 May 2005
- journal article
- abdominal imaging
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 29 (3) , 387-393
- https://doi.org/10.1097/01.rct.0000160985.66259.96
Abstract
Objective: To investigate inter- and intraobserver agreement of automated measurement of polyp diameter in vitro. Methods: Two phantoms (“QRM” and “Whiting”) containing simulated polyps of known diameter and volume were scanned using 16-detector row computed tomography. Two observers estimated polyp diameter using 3 methods: software calipers (“manual”), freehand boundary identification (“semiautomatic”), and automated software segmentation (“fully automatic”). Results: Intraobserver 95% limits of agreement for diameter were narrowest for the fully automatic method (QRM span: 0.39 mm, 0.48 mm; Whiting span: 0.24 mm, 0 mm). Manual estimates were approximately 10 times wider (QRM span: 3.57 mm, 3.21 mm; Whiting span: 3.2 mm, 2.02 mm). Volume estimates were narrowest for the fully automatic method (span: 24.2 mm3, 24.1 mm3 vs. 97.9 mm3, 102.9 mm3 for semiautomatic measurement). Interobserver agreement for diameter was narrowest for the fully automatic method (QRM span: 0.12 mm, Whiting span: 0.16 mm), with the manual method approximately 18 times wider (QRM span: 2.87 mm, Whiting span: 2.18 mm). Conclusion: Fully automated measurement of polyp diameter and volume is technically feasible and results in superior inter- and intraobserver agreement.Keywords
This publication has 13 references indexed in Scilit:
- A prospective study of colonoscopy practice in the UK today: are we adequately prepared for national colorectal cancer screening tomorrow?Gut, 2004
- Computed Tomographic Virtual Colonoscopy to Screen for Colorectal Neoplasia in Asymptomatic AdultsNew England Journal of Medicine, 2003
- Prospective blinded evaluation of computed tomographic colonography for screen detection of colorectal polypsGastroenterology, 2003
- Computer-aided Diagnosis Scheme for Detection of Polyps at CT ColonographyRadioGraphics, 2002
- Influence of Image Acquisition Parameters on CT Artifacts and Polyp Depiction in Spiral CT Colonography: In Vitro EvaluationRadiology, 2000
- Is in vivo measurement of size of polyps during colonoscopy accurate?Gastrointestinal Endoscopy, 1997
- The pathologic measurement of polyp size is preferable to the endoscopic estimateGastrointestinal Endoscopy, 1997
- The difference in colon polyp size before and after removalGastrointestinal Endoscopy, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986