A finite-element model of the mechanical effects of implantable microelectrodes in the cerebral cortex
Top Cited Papers
- 11 October 2005
- journal article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 2 (4) , 103-113
- https://doi.org/10.1088/1741-2560/2/4/006
Abstract
The viability of chronic neural microelectrodes for electrophysiological recording and stimulation depends on several factors, including the encapsulation of the implant by a reactive tissue response. We postulate that mechanical strains induced around the implant site may be one of the leading factors responsible for the sustained tissue response in chronic implants. The objectives of this study were to develop a finite-element model of the probe-brain tissue interface and analyze the effects of tethering forces, probe-tissue adhesion and stiffness of the probe substrate on the interfacial strains induced around the implant site. A 3D finite-element model of the probe-brain tissue microenvironment was developed and used to simulate interfacial strains created by 'micromotion' of chronically implanted microelectrodes. Three candidate substrates were considered: (a) silicon, (b) polyimide and (c) a hypothetical 'soft' material. Simulated tethering forces resulted in elevated strains both at the tip and at the sharp edges of the probe track in the tissue. The strain fields induced by a simulated silicon probe were similar to those induced by a simulated polyimide probe, albeit at higher absolute values for radial tethering forces. Simulations of poor probe-tissue adhesion resulted in elevated strains at the tip and delamination of the tissue from the probe. A tangential tethering force results in 94% reduction in the strain value at the tip of the polyimide probe track in the tissue, whereas the simulated 'soft' probe induced two orders of magnitude smaller values of strain compared to a simulated silicon probe. The model results indicate that softer substrates reduce the strain at the probe-tissue interface and thus may also reduce tissue response in chronic implants.Keywords
This publication has 38 references indexed in Scilit:
- Chronic Neural Recording Using Silicon-Substrate Microelectrode Arrays Implanted in Cerebral CortexIEEE Transactions on Biomedical Engineering, 2004
- Chemical sensing capability of MEMS implantable multichannel neural microelectrode arraysPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2004
- Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activityBiosensors and Bioelectronics, 2004
- 3D flexible multichannel neural probe arrayJournal of Micromechanics and Microengineering, 2003
- Silicon-substrate intracortical microelectrode arrays for long-term recording of neuronal spike activity in cerebral cortexIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2003
- A shuttered probe with in-line flowmeters for chronic in-vivo drug deliveryPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Flexible polyimide-based intracortical electrode arrays with bioactive capabilityIEEE Transactions on Biomedical Engineering, 2001
- A multichannel neural probe for selective chemical delivery at the cellular levelIEEE Transactions on Biomedical Engineering, 1997
- Mechanical properties of tissues of the nervous systemJournal of Biomechanics, 1968
- Deformation and fracture of small silicon crystalsActa Metallurgica, 1957