An Improved, Computer‐based Method to Automatically Track Internal and External Diameter of Isolated Microvessels
- 1 June 2005
- journal article
- research article
- Published by Wiley in Microcirculation
- Vol. 12 (4) , 361-372
- https://doi.org/10.1080/10739680590934772
Abstract
Objective: To develop an automated diameter tracking method suitable for studies of isolated, perfused microvessels (< 100 μ m internal diameter (ID)). Methods: A diameter tracking method was implemented in conjunction with a standard PC workstation and video card. Within a user‐defined window, the algorithm combined thresholding and iterative regression procedures to detect the average outer diameter (OD) of a vertically oriented microvessel. After an initial ID measurement by the user, the program continuously calculated ID based on the assumption of an incompressible vessel wall. Results: The program, Vessel Track, was tested against a manual video caliper and two analog video dimension analyzers. Vessel Track was capable of accurately following arteriolar dimensions during extreme vasodilation and vasoconstriction. It provided more accurate, lower‐noise recordings than either of the video dimension analyzers, particularly after strong vasoconstriction during which lumenal folds developed. Vessel Track also was capable of accurately measuring large‐amplitude vasomotion in isolated lymphatic vessels at a tracking frequency of ∼ 30 times/s. Conclusions: Vessel Track should be useful for automated diameter tracking of isolated arterioles, venules, and lymphatics. With suitable preparations, it provides fast, stable measurements of ID in microvessels even with irregular lumen geometry.Keywords
This publication has 15 references indexed in Scilit:
- Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic ductThe Journal of Physiology, 2002
- α 4 β 1 Integrin Activation of L-Type Calcium Channels in Vascular Smooth Muscle Causes Arteriole VasoconstrictionCirculation Research, 2002
- Force-velocity relationship of myogenically active arteriolesAmerican Journal of Physiology-Heart and Circulatory Physiology, 2002
- Real-Time Measurement of Microvascular Dimensions Using Digital Cross-Correlation Image ProcessingJournal of Vascular Research, 1992
- Reactive oxygen metabolites inhibit spontaneous lymphatic contractionsAmerican Journal of Physiology-Heart and Circulatory Physiology, 1991
- Cannulation and continuous cross-sectional area measurement of small blood vesselsJournal of Pharmacological Methods, 1990
- Digital video image-shearing device for continuous microvessel diameter measurementMicrovascular Research, 1987
- Mechanical behavior of pressurized in vitro prearteriolar vessels determined with a video systemAnnals of Biomedical Engineering, 1984
- A digital video image splitting device for microvascular measurementsMicrovascular Research, 1984
- Microvascular measurements by video image shearing and splittingMicrovascular Research, 1973