Two-dimensional restoration of single photon emission computed tomography images using the Kalman filter
- 1 March 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 13 (1) , 102-109
- https://doi.org/10.1109/42.276148
Abstract
The discrete filtered backprojection (DFBP) algorithm used for the reconstruction of single photon emission computed tomography (SPECT) images affects image quality because of the operations of filtering and discretization. The discretization of the filtered backprojection process can cause the modulation transfer function (MTF) of the SPECT imaging system to be anisotropic and nonstationary, especially near the edges of the camera's field of view. The use of shift-invariant restoration techniques fails to restore large images because these techniques do not account for such variations in the MTF. This study presents the application of a two-dimensional (2D) shift-variant Kalman filter for post-reconstruction restoration of SPECT slices. This filter was applied to SPECT images of a hollow cylinder phantom; a resolution phantom; and a large, truncated cone phantom containing two types of cold spots, a sphere, and a triangular prism. The images were acquired on an ADAC GENESYS camera. A comparison was performed between results obtained by the Kalman filter and those obtained by shift-invariant filters. Quantitative analysis of the restored images performed through measurement of root mean squared errors shows a considerable reduction in error of Kalman-filtered images over images restored using shift-invariant methods.Keywords
This publication has 39 references indexed in Scilit:
- Activity quantitation in SPECT: A study of prereconstruction Metz filtering and use of the scatter degradation factorMedical Physics, 1991
- Restoration of combined conjugate images in SPECT: comparison of a new Wiener filter and the image-dependent Metz filterIEEE Transactions on Nuclear Science, 1990
- Restoration of gamma camera-based nuclear medicine imagesIEEE Transactions on Medical Imaging, 1989
- Digital Restoration of Scintigraphic Images by a Two-Step ProcedureIEEE Transactions on Medical Imaging, 1987
- Optimal preprocessing Butterworth-Wiener filter for Tl-201 myocardial SPECTEuropean Journal of Nuclear Medicine and Molecular Imaging, 1987
- A Wiener filter for nuclear medicine imagesMedical Physics, 1983
- SPECT: Single Photon Emission Computed TomographyIEEE Transactions on Nuclear Science, 1980
- The Characteristics of Computed Tomographic Reconstruction Noise and Their Effect on DetectabilityIEEE Transactions on Nuclear Science, 1978
- New results in 2-D systems theory, part II: 2-D state-space models—Realization and the notions of controllability, observability, and minimalityProceedings of the IEEE, 1977
- A new look at the statistical model identificationIEEE Transactions on Automatic Control, 1974