Programmable VT Detection Enhancements in Implantable Cardioverter Defibrillator Therapy
- 1 March 1995
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 18 (3) , 539-547
- https://doi.org/10.1111/j.1540-8159.1995.tb02564.x
Abstract
This report describes the distribution of automatically measured values of enhanced arrhythmia detection parameters such as "rate stability" and "rate onset" in various forms of spontaneous arrhythmia episodes in patients treated with a new, third-generation, tiered therapy implantable cardioverter defibrillator (ICD). The study population consisted of 27 patients who received the Ventak PRxII cardioverter defibrillator, which provides extensive diagnostic options such as electrogram storage capabilities, and the ability to store measured values of additional arrhythmia detection parameters such as rate stability and rate onset during spontaneous arrhythmia episodes. During a follow-up period of 11.1 +/- 5.2 months, this device detected 264 arrhythmia episodes. The analysis of stored electrograms revealed 13 episodes of sinus tachycardia, 52 episodes of atrial tachyarrhythmias, and 201 episodes of monomorphic ventricular tachycardias (VTs). The mean measured values of rate stability and rate onset were: 2.2 +/- 0.9 msec, 0% in sinus tachycardias; 41.0 +/- 24.1 msec, 8.5% +/- 9.5% in atrial tachyarrhythmias; and 7.8 +/- 6.0 msec, 30.6% +/- 12.1% in monomorphic VTs. There was a wide zone of overlapping measured values for rate stability and rate onset in ventricular and nonventricular rhythms. No episode of VT showed a measured rate stability criterion > 35 msec. The subanalysis of arrhythmia episodes presenting with a heart rate < 160 beats/min revealed no episode of VT with a rate stability value > 24 msec. The calculated, rate dependent specificities for these programmed rate stability parameters in detecting VTs were 46.2% and 81.8%, respectively. The analysis of the rate onset algorithm revealed no comparable relationship between sensitivity and specificity in the detection of VTs.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 20 references indexed in Scilit:
- Implantable cardioverter-defibrillator therapy in the absence of significant symptoms. Rhythm diagnosis and management aided by stored electrogram analysis.Circulation, 1993
- Electrocardiographically Documented Unnecessary, Spontaneous Shocks in 241 Patients With Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1992
- Holter Documented Sudden Death in a Patient with an Implanted DefibrillatorPacing and Clinical Electrophysiology, 1992
- Implantable Cardioverter Defibrillator Proarrhythmia: Case Report and Review of the LiteraturePacing and Clinical Electrophysiology, 1991
- Clinical Performance of the Implantable Cardioverter Defibrillator: Electrocardiographic Documentation of 101 Spontaneous DischargesPacing and Clinical Electrophysiology, 1991
- Actuarial Incidence and Pattern of Occurrence of Shocks Following Implantation of the Automatic Implantable Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1989
- Erroneous discharge from an implanted automatic defibrillator during supraventricular tachyarrhythmia induced ventricular fibrillationThe American Journal of Cardiology, 1986
- Discrimination of Supraventricular Tachycardia from Sinus Tachycardia of Overlapping Cycle LengthPacing and Clinical Electrophysiology, 1984
- Maximal Rate of Tachycardia Development: Sinus Tachycardia with Sudden Exercise vs. Spontaneous Ventricular TachycardiaPacing and Clinical Electrophysiology, 1983
- Ventricular Response in Atrial FibrillationCirculation Research, 1966