Evaluating the Reproducibility of Topography Systems on Spherical Surfaces
- 1 February 1993
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 111 (2) , 259-262
- https://doi.org/10.1001/archopht.1993.01090020113034
Abstract
• Newly devised software was used to compare the ability of the Topographic Modeling System-1 (Computed Anatomy, New York, NY) and the Corneal Analysis System (EyeSys Laboratories, Houston, Tex) to reproduce power measurements on spherical surfaces. Reproducibility results were compared for spheres of 40.00, 42.50, and 44.00 diopters. The program determines the absolute difference in corneal power at defined keratoscope positions for paired examinations of the same eye. Four examinations of each sphere were obtained with each instrument. Individual points were sampled at specific keratoscope locations at 30°-semimeridional intervals. The program compared variability of measurements at four defined ranges of distance from the vertex normal: within 0.60 mm, 0.61 to 1.5 mm, 1.51 to 2.5 mm, and 2.5 mm or greater. The Corneal Analysis System showed significantly greater variability of readings obtained within 0.60 mm of the vertex normal for all three spheres (P=.001 by Duncan's multiple comparison procedure), whereas the Topographic Modeling System-1 showed equally consistent readings within 0.60 mm as it did between 0.61 and 1.5 mm from the vertex normal.Keywords
This publication has 10 references indexed in Scilit:
- Diurnal Variation of Corneal Topography After Radial KeratotomyArchives of Ophthalmology (1950), 1992
- Corneal Topographic Changes Following Strabismus Surgery in Graves?? DiseaseCornea, 1992
- Accuracy and Precision of the Corneal Analysis System and the Topographic Modeling SystemCornea, 1992
- Changes in Corneal Topography after Excimer Laser Photorefractive Keratectomy for MyopiaOphthalmology, 1991
- Identifying Progression of Subclinical Keratoconus by Serial Topography AnalysisAmerican Journal of Ophthalmology, 1991
- Advances in the analysis of corneal topographySurvey of Ophthalmology, 1991
- Reproducibility of Normal Corneal Power Measurements With a Keratometer, Photokeratoscope, and Video Imaging SystemArchives of Ophthalmology (1950), 1990
- Accuracy and Precision of Keratometry, Photokeratoscopy, and Corneal Modeling on Calibrated Steel BallsArchives of Ophthalmology (1950), 1989
- Corneal ModelingCornea, 1988
- Graphic Presentation of Computer-Analyzed Keratoscope PhotographsArchives of Ophthalmology (1950), 1987