Sensitivity and specificity of scanning laser polarimetry using the GDx
Open Access
- 1 September 2004
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 88 (9) , 1142-1145
- https://doi.org/10.1136/bjo.2003.036756
Abstract
Background/aims: To determine the sensitivity and the specificity of the GDx in the detection of (1) advanced glaucoma, (2) early glaucoma, and (3) nerve fibre bundle defects (NFBD). Methods: Group A comprised 20 eyes with reproducible glaucomatous visual field defects confirmed by octopus perimetry, group B consisted of 10 eyes with normal visual fields but either glaucomatous NFBD or deterioration of the disc over time clearly visible upon flicker comparison, and group C included 16 eyes with glaucomatous or non-glaucomatous NFBD clearly visible on red free photographs. Forty four eyes of 22 healthy volunteers served as controls. The GDx printouts of all subjects were evaluated by three independent observers in a masked fashion and without the clinical picture of the optic disc. Two of the three observers (SK, UH) were GDx experts, one (KUL) was an untrained GDx user. Results: Among the GDx experts, sensitivity/specificity was 100%/100% (SK) and 90%/100% (UH) in detecting advanced glaucoma, and 100%/100% (SK) and 90%/100% (UH) in detecting early glaucoma. The sensitivity in detecting NFBD was only 37.5% (SK and UH). For the untrained GDx user the corresponding values were 50%/100% (group A), 20%/100% (group B), and 12.5%/91% (group C). Conclusion: Detection of (early) glaucoma damage by the GDx, evaluated by trained experts, can be extremely high. To optimise its benefit in clinical routine training in interpreting GDx printouts is highly recommended. Detection of localised NFBD is crucial, even for experts.Keywords
This publication has 18 references indexed in Scilit:
- Sensitivity and Specificity of the GDx: Clinical Judgment of Standard Printouts Versus the NumberJournal of Glaucoma, 2003
- Screening Performance of Functional and Structural Measurements of Neural Damage in Open-Angle Glaucoma: A Case-Control Study From the Baltimore Eye SurveyJournal of Glaucoma, 2000
- The Sensitivity and Specificity of Nerve Fiber Layer Measurements in Glaucoma as Determined With Scanning Laser PolarimetryAmerican Journal of Ophthalmology, 1997
- Scanning Laser Polarimetry to Measure the Nerve Fiber Layer of Normal and Glaucomatous EyesAmerican Journal of Ophthalmology, 1995
- Initial Glaucomatous Optic Disk and Retinal Nerve Fiber Layer Abnormalities and Their ProgressionAmerican Journal of Ophthalmology, 1991
- Histopathologic Validation of Fourier-Ellipsometry Measurements of Retinal Nerve Fiber Layer ThicknessArchives of Ophthalmology (1950), 1990
- Neuroretinal Rim Area and Retinal Nerve Fiber Layer in GlaucomaArchives of Ophthalmology (1950), 1985
- Quantitative Studies of Retinal Nerve Fiber Layer DefectsArchives of Ophthalmology (1950), 1982
- Clinical Evaluation of Nerve Fiber Layer Atrophy as an Indicator of Glaucomatous Optic Nerve DamageArchives of Ophthalmology (1950), 1980
- THE EARLIEST OBSERVABLE DEFECT IN GLAUCOMA ?The Lancet, 1972