Quantitative analysis of selected PCB congeners in marine matrix reference materials using a novel cyanobiphenyl stationary phase
- 1 February 1995
- journal article
- research article
- Published by Wiley in Journal of High Resolution Chromatography
- Vol. 18 (2) , 89-96
- https://doi.org/10.1002/jhrc.1240180204
Abstract
A novel p,p‐cyanobiphenyl stationary phase (p‐cyanobiphenyl, p‐allyloxy methylpolysiloxane) has been evaluated for the GC investigation of polychlorinated biphenyls (PCBs). Several PCB congeners which coelute on the phases typically used for PCB analysis (e.g. 5% phenyl methylpolysiloxane) are separated on the p,p‐cyanobiphenyl phase, including the hexachlorobiphenyl congeners PCB 163, PCB 164, and PCB 138. In this work, a p,p‐cyanobiphenyl stationary phase was used to measure selected PCB congeners in two Standard Reference Materials (SRMs) available from the National Institute of Standards and Technology (NIST), and two Certified Reference Materials (CRMs) available from the Community Bureau of Reference (BCR). The materials analyzed were SRM 1588, Organics in Cod Liver Oil; SRM 1945, Organics in Whale Blubber; CRM 349, Chlorobiphenyls in Cod Liver Oil; and CRM 350, Chlorobiphenyls in Mackerel Oil. Concentrations are reported for several PCB congeners which coelute on the 5% phenyl methylpolysiloxane, including PCB 163 and PCB 164.Keywords
This publication has 24 references indexed in Scilit:
- Long chain alkyl-polysiloxanes as non-polar stationary phases in capillary gas chromatographyAnalytical and Bioanalytical Chemistry, 1993
- Comparison of methods for the gas-chromatographic determination of PCB congeners and chlorinated pesticides in marine reference materialsAnalytical and Bioanalytical Chemistry, 1993
- Comparative analysis of thirty polychlorinated biphenyl congeners on two capillary columns of different polarity with non-linear multi-level calibrationJournal of Chromatography A, 1991
- Interferences in the Determination of 2,4,5,2′,5′-Pentachlorobiphenyl (CB 101) in Environmental and Technical SamplesInternational Journal of Environmental Analytical Chemistry, 1991
- Interference from 2,3,5,6-3?,4?-Hexachlorobiphenyl (CB 163) in the Determination of 2,3,4-2?,4?,5?-Hexachlorobiphenyl (CB 138) in Environmental and Technical SamplesInternational Journal of Environmental Analytical Chemistry, 1990
- Review: Biological Activity, Determination and Occurrence of Planar, Mono- and Di-Ortho PCBsInternational Journal of Environmental Analytical Chemistry, 1990
- Problems Encountered in the Determination of 2,3,4-2′4′5′ Hexachlorobiphenyl (CB 138) in Environmental SamplesInternational Journal of Environmental Analytical Chemistry, 1989
- Complete characterization of polychlorinated biphenyl congeners in commercial Aroclor and Clophen mixtures by multidimensional gas chromatography-electron capture detectionEnvironmental Science & Technology, 1989
- High-resolution PCB analysis: synthesis and chromatographic properties of all 209 PCB congenersEnvironmental Science & Technology, 1984
- Analysis of polychlorinated biphenyls (PCB) by glass capillary gas chromatographyAnalytical and Bioanalytical Chemistry, 1980