Simultaneous Serodetection of 10 Highly Prevalent Mouse Infectious Pathogens in a Single Reaction by Multiplex Analysis
Open Access
- 1 April 2005
- journal article
- research article
- Published by American Society for Microbiology in Clinical and Vaccine Immunology
- Vol. 12 (4) , 513-519
- https://doi.org/10.1128/cdli.12.4.513-519.2005
Abstract
Under current practices of mouse colony maintenance, sera from mice are analyzed for antibodies against several widespread infectious pathogens by conventional immunoassays, generally enzyme-linked immunosorbent assay (ELISA). To test for multiple agents, these methods consume large volumes of mouse serum and are laborious and time-consuming. More efficient immunoassays, using small amounts of sample, are therefore needed. Accordingly, we have developed a novel multiplex diagnostic system that employs fluorescent microbeads, coated with purified antigens, for simultaneous serodetection of 10 mouse infectious agents. Individually identifiable, fluorescent microbeads were coated with antigens from Sendai virus, mouse hepatitis virus, Theiler's mouse encephalomyelitis virus/GDVII strain, mouse minute virus, mouse cytomegalovirus, respiratory enteric orphan virus (Reo-3 virus), mouse parvovirus, calf rotavirus for epizootic diarrhea virus of infant mice, vaccinia virus for ectromelia virus, and Mycoplasma pulmonis . Standard sera, singly positive for antibodies to individual infectious agents, were generated by inoculation of BALB/cj and C57BL/6j mice. Sera from these experimentally infected mice, as well as sera from naturally infected mice, were analyzed using a mixture of microbeads coated with antigens of the 10 infectious agents listed above. Results demonstrated that the multiplex assay was at least as sensitive and specific as ELISA for serodetection. Importantly, the multiplex assay required only 1 microliter of serum for simultaneous serodetection of the 10 mouse infectious agents in one reaction vessel. Thus, this multiplex microbead assay is a reliable, efficient, and cost-effective diagnostic modality that will impact serosurveillance of mice used in research.Keywords
This publication has 17 references indexed in Scilit:
- New multiplexed flow cytometric assay to measure anti‐peptide antibody: a novel tool for monitoring immune responses to peptides used for immunizationScandinavian Journal of Clinical and Laboratory Investigation, 2004
- Efficacy of three microbiological monitoring methods in a ventilated cage rack.2004
- Rodent vendor apparent source of mouse parvovirus in sentinel mice.2004
- Autoantibodies Profile in the Sera of Patients with Sjogren]s Syndrome: The ANA Evaluation—A Homogeneous, Multiplexed SystemClinical and Developmental Immunology, 2004
- Simultaneous Quantitation of Antibodies to Neutralizing Epitopes on Virus-Like Particles for Human Papillomavirus Types 6, 11, 16, and 18 by a Multiplexed Luminex AssayClinical and Vaccine Immunology, 2003
- Serodiagnosis of Mice Minute Virus and Mouse Parvovirus Infections in Mice by Enzyme-Linked Immunosorbent Assay with Baculovirus-Expressed Recombinant VP2 ProteinsClinical and Vaccine Immunology, 2002
- Comparison of a Multiplex Flow Cytometric Assay with Enzyme-Linked Immunosorbent Assay for Quantitation of Antibodies to Tetanus, Diphtheria, and Haemophilus influenzae Type bClinical and Vaccine Immunology, 2002
- A Multiplexed Fluorescent Microsphere Immunoassay for Antibodies to Pneumococcal Capsular PolysaccharidesAmerican Journal of Clinical Pathology, 2002
- Development of Internal Controls for the Luminex Instrument as Part of a Multiplex Seven-Analyte Viral Respiratory Antibody ProfileClinical and Vaccine Immunology, 2002
- SEROLOGICAL SURVEY OF LABORATORY RODENTS FOR INFECTION WITH SENDAI VIRUS, MOUSE HEPATITIS VIRUS, REOVIRUS TYPE 3 AND MOUSE ADENOVIRUSJapanese Journal of Medical Science and Biology, 1982