Improving FAIMS sensitivity using a planar geometry with slit interfaces
- 1 September 2009
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 20 (9) , 1768-1774
- https://doi.org/10.1016/j.jasms.2009.05.019
Abstract
Differential mobility spectrometry or field asymmetric waveform ion mobility spectrometry (FAIMS) is gaining broad acceptance for analyses of gas-phase ions, especially in conjunction with largely orthogonal separation methods such as mass spectrometry (MS) and/or conventional (drift tube) ion mobility spectrometry. In FAIMS, ions are filtered while passing through a gap between two electrodes that may have planar or curved (in particular, cylindrical) geometry. Despite substantial inherent advantages of the planar configuration and its near-universal adoption in current stand-alone FAIMS devices, commercial FAIMS/MS systems have employed curved FAIMS geometries that can be more effectively interfaced to MS. Here we report a new planar (p-) FAIMS design with slit-shaped entrance and exit apertures that substantially increase ion transmission in and out of the analyzer. The entrance slit interface effectively couples p-FAIMS to multi-emitter electrospray ionization (ESI) sources, improving greatly the ion current introduced to the device and allowing liquid flow rates up to ∼50 µL/min. The exit slit interface increases the transmission of ribbon-shaped ion beams output by the p-FAIMS to downstream stages such as a MS. Overall, the ion signal in ESI/FAIMS/MS analyses increases by over an order of magnitude without affecting FAIMS resolution.Keywords
This publication has 49 references indexed in Scilit:
- Assessing the Dynamic Range and Peak Capacity of Nanoflow LC−FAIMS−MS on an Ion Trap Mass Spectrometer for ProteomicsAnalytical Chemistry, 2008
- Analytical Characterization of the Electrospray Ion Source in the Nanoflow RegimeAnalytical Chemistry, 2008
- Nanoelectrospray Emitter Arrays Providing Interemitter Electric Field UniformityAnalytical Chemistry, 2008
- Capillary-Based Multi Nanoelectrospray Emitters: Improvements in Ion Transmission Efficiency and Implementation with Capillary Reversed-Phase LC-ESI-MSAnalytical Chemistry, 2007
- Chemically Etched Open Tubular and Monolithic Emitters for Nanoelectrospray Ionization Mass SpectrometryAnalytical Chemistry, 2006
- Compensation voltage shifting in high‐field asymmetric waveform ion mobility spectrometry‐mass spectrometryRapid Communications in Mass Spectrometry, 2006
- High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry AnalyzersAnalytical Chemistry, 2006
- Enhanced Mixture Analysis of Poly(ethylene glycol) Using High-Field Asymmetric Waveform Ion Mobility Spectrometry Combined with Fourier Transform Ion Cyclotron Resonance Mass SpectrometryAnalytical Chemistry, 2006
- Analytical Properties of the Nanoelectrospray Ion SourceAnalytical Chemistry, 1996
- A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric fieldInternational Journal of Mass Spectrometry and Ion Processes, 1993