Platelet and monoclonal antibody binding to fibrinogen adsorbed on glow‐discharge‐deposited polymers
- 1 June 1995
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 29 (6) , 729-739
- https://doi.org/10.1002/jbm.820290609
Abstract
The state of fibrinogen adsorbed on untreated and glow-discharge-treated surfaces was examined by measuring platelet adhesion, monoclonal antibody (mAb) binding, the amount of fibrinogen adsorbed, and the amount of adsorbed fibrinogen which could be eluted with sodium dodecyl sulfate (SDS). Tetrafluoroethylene (TFE) glow-discharge-treated polymers have a lower surface free energy (in air) and retain a larger fraction of adsorbed fibrinogen than untreated surfaces after SDS elution. Platelet adhesion was lowest on the TFE-treated surfaces which retain the highest amounts of fibrinogen after SDS elution. Fibrinogen may undergo unfolding or spreading on the TFE-treated surfaces to minimize interfacial free energy (in water) and maximize protein–;surface interactions. When it is adsorbed on the TFE-treated surfaces, fibrinogen evidently assumes a state which somehow prevents its recognition and binding by platelet receptors. Monoclonal antibodies that bind to the three regions in fibrinogen thought to be involved in platelet adhesion were therefore used to detect changes in adsorbed fibrinogen. These regions and the antibodies which bind to them are: the COOH-terminal of the γ-chain, mAb M1; the RGD peptide sequence at Aα 95–98, mAb R1; the RDG sequence at Aα 572–575, mAb R2. For fibrinogen adsorbed on the untreated or TFE-treated surfaces, M1 and R2 binding was relatively high compared to background, while R1 binding was low. However, the amount of binding of each mAb to fibrinogen adsorbed on the TFE-treated surfaces was equal to or greater than fibrinogen adsorbed to the untreated surfaces. Therefore, antibody-detectable changes in the platelet binding regions of adsorbed fibrinogen that might have been caused by conformational or orientational rearrangements were not observed for the TFE-treated surfaces. The data suggest that the tight binding of fibrinogen on a surface may directly affect the ability of the fibrinogen to interact with the platelet receptors—i.e., that fibrinogen must be loosely held to facilitate maximal interaction with platelet receptors. © 1995 John Wiley & Sons, Inc.Keywords
This publication has 21 references indexed in Scilit:
- Residence time effects on monoclonal antibody binding to adsorbed fibrinogenJournal of Biomaterials Science, Polymer Edition, 1995
- Adherent platelet morphology on adsorbed fibrinogen: Effects of protein incubation time and albumin additionJournal of Biomedical Materials Research, 1994
- Influence of the substrate binding characteristics of fibronectin on corneal epithelial cell outgrowthJournal of Biomedical Materials Research, 1992
- Plasma gas discharge deposited fluorocarbon polymers exhibit reduced elutability of adsorbed albumin and fibrinogenJournal of Biomaterials Science, Polymer Edition, 1989
- Role of Fibrinogen in Activation of Platelets by Artificial SurfacesAnnals of the New York Academy of Sciences, 1987
- Redistribution of the fibrinogen receptor of human platelets after surface activation.The Journal of cell biology, 1984
- Plasma Proteins: Their Role in Initiating Platelet and Fibrin Deposition on BiomaterialsPublished by American Chemical Society (ACS) ,1982
- A surface energy analysis of bioadhesionPolymer, 1977
- Efficient Trace-labelling of Proteins with IodineNature, 1958