Digital videofluorography for direct digital spot filming of gastrointestinal studies
- 1 December 1989
- journal article
- research article
- Published by Springer Nature in Gastrointestinal Radiology
- Vol. 14 (1) , 193-201
- https://doi.org/10.1007/bf01889195
Abstract
Digital videofluorography (DVF) refers to a new computer-aided televised fluoroscopy technique that uses short (10–20 ms) intense pulses of radiation to produce a motion-free latent image, which is then transferred into digital storage. Because gastrointestinal imaging has lagged behind other body systems in the evaluation of digital acquisition, we investigated the potential utility of this technique for direct digital fluoroscopic spot filming of gastrointestinal examinations. In order to assess the level of clinical image quality achieved by this technique, we conducted an observer performance comparison study of digitally acquired and conventional analog 100 mm spot films. Sequentially acquired spot films and digital radiographs of 111 anatomic regions in 60 patients undergoing routine barium and cholangiographic examinations were compared. Evaluation was made of on-line interactive performance as well as side-by-side analysis of digital and analog hard copy images. Parameters evaluated include detection of normal and pathologic features, image contrast, image resolution, and image sharpness. Direct digital and analog spot films were of comparable diagnostic quality in all parameters studied. Added benefits of the digital mode included postprocessing to enhance detail in regions of low contrast and accommodation of a large field of view (14 inch) image intensifier format.This publication has 10 references indexed in Scilit:
- Low-dose flying spot digital radiography of the chest: sensitivity studies.Radiology, 1987
- Digital gastrointestinal imaging: the effect of pixel size on detection of subtle mucosal abnormalities.Radiology, 1987
- Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules.Radiology, 1986
- Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance.Radiology, 1986
- Clinical Application Of High Resolution Digital Image Storage For General RadiographyPublished by SPIE-Intl Soc Optical Eng ,1985
- Exposure equalization radiography of the chest: clinical comparison of slit and raster scanning techniquesAmerican Journal of Roentgenology, 1985
- Videofluorography and pulsed fluoroscopy using a 512 X 512-pixel digital image system.Radiology, 1985
- Digital radiography of the chest: clinical experience with a prototype unit.Radiology, 1983
- Clinical experience with combined videofluorography and pulsed fluoroscopy.Radiology, 1982