Effect of seafood consumption on the urinary level of total hydride-generating arsenic compounds. Instability of arsenobetaine and arsenocholine
- 1 January 1992
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 117 (3) , 677-680
- https://doi.org/10.1039/an9921700677
Abstract
Arsenobetaine and arsenocholine are considered to be non-toxic and are present as a relatively large proportion of total arsenic in seafoods, and they do not respond to hydride generation. The present study describes the effect of seafood consumption on the urinary concentration of hydride-generating arsenic compounds measured by a newly developed flow injection atomic absorption spectrometric (FI-AAS) method. Consumption of plaice, pighvar and tunny resulted in a 2-fold increase, and consumption of mussels produced a 6-fold increase in the urinary level of hydride-generating arsenic compounds. Hence, a person who has consumed mussels may be suspected of being occupationally or environmentally exposed, if the level of consumption of this seafood is unknown. As the FI-AAS method cannot be used to detect arsenobetaine and arsenocholine, the observed increase in urinary concentration of hydride-generating arsenic compounds after consumption of seafood must originate either from hydride-generating arsenic compounds in the seafood or from degraded arsenobetaine or arsenocholine. The present study has demonstrated that both arsenobetaine and arsenocholine are unstable when incubated in daylight in the presence of hydrogen peroxide, i.e., an oxidizing environment. Hence, it is tempting to speculate that arsenobetaine could be converted into hydride-generating arsenic compounds during storage or cooking of seafood. The feasibility of speciation methods based on high-performance liquid chromatographic (HPLC) separation and on-line analysis by inductively coupled plasma atomic emission spectrometry (ICP-AES) and FI-AAS was also investigated. The FI-AAS system is approximately 35 times more sensitive to the hydride-generating arsenic species than the ICP-AES system. Consequently, an HPLC–FI-AAS speciation method could be useful in analyses for arsenic species in urine from highly exposed persons, or persons suspected of being unable to, or having a reduced ability to, methylate inorganic arsenic compounds.Keywords
This publication has 11 references indexed in Scilit:
- On-line photo-oxidation for the determination of organoarsenic compounds by atomic-absorption spectrometry with continuous arsine generationTalanta, 1991
- Electrothermal atomic absorption spectrometry of inorganic and organic arsenic species using conventional and fast furnace programmesJournal of Analytical Atomic Spectrometry, 1991
- The effect of variable environmental arsenic contamination on urinary concentrations of arsenic species.Environmental Health Perspectives, 1990
- Pathways of human exposure to arsenic in a community surrounding a copper smelterEnvironmental Research, 1990
- The photo-oxidation of solutions of arsenicals to arsenate: A convenient analytical procedureApplied Organometallic Chemistry, 1988
- Urinary arsenic speciation by high-performance liquid chromatography/atomic absorption spectrometry for monitoring occupational exposure to inorganic arsenicAnalytica Chimica Acta, 1987
- Arsenic Speciation in Urine from Humans Intoxicated by Inorganic Arsenic CompoundsHuman Toxicology, 1985
- The speciation of the chemical forms of arsenic in the biological monitoring of exposure to inorganic arsenicScience of The Total Environment, 1984
- Reduction of electronic noise in inductively coupled plasma atomic emission and fluorescence spectrometric measurementsAnalytical Chemistry, 1983
- A rapid method for the selective analysis of total urinary metabolites of inorganic arsenic.Scandinavian Journal of Work, Environment & Health, 1981