Response of End-Window Photomultiplier Tubes as a Function of Temperature
- 1 June 1960
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IRE Transactions on Nuclear Science
- Vol. 7 (2/3) , 80-86
- https://doi.org/10.1109/tns2.1960.4315742
Abstract
This paper reports a study of the response of commercial end-window photomultipliers to light of various wavelengths, in the 4000 to 7000 A interval, as a function of temperature. All tubes studied were of nominal 2-inch diameter, and included various standard tubes made by DuMont and RCA, low-temperature modifications of standard tubes, and the recently-developed multialkali-photocathode tubes. Most of the experiments were performed with the tube operating as a multiplier; in a series of auxiliary experiments, the dynode string was shorted to the anode so that the effect of cooling the cathode could be studied separately. In a typical tube the response to blue light increases somewhat with decreasing temperature, whereas the response to red light decreases rapidly; these effects are associated with changes in the photocathode spectral sensitivity. At low temperatures (~-100°C or below) the response falls sharply for all wavelengths, an effect attributed to the increased resistivity of the semiconducting photocathode. This effect is not observed in tubes whose photocathode is covered with a semitransparent metallic backing. The temperature dependence of spectral sensitivity in multialkali-photocathodes (RCA C-7261) is significantly different from that of a Cs-Sb photocathode.Keywords
This publication has 10 references indexed in Scilit:
- Le coefficient de température de l'effet photoélectrique des métauxJournal de Physique et le Radium, 1959
- Fundamental Studies of Scintillation Phenomena in NaIIRE Transactions on Nuclear Science, 1958
- Recent Work on Photoemission and Dark Emission ProblemsIRE Transactions on Nuclear Science, 1958
- Fatigue in PhotomultipliersIRE Transactions on Nuclear Science, 1958
- Use of Li6I(Eu) as a scintillation detector and spectrometer for fast neutronsNuclear Instruments, 1958
- Influence de la température sur les photomultiplicateurs et les scintillateurs liquidesJournal de Physique et le Radium, 1958
- Temperature coefficients of scintillating systemsNuclear Instruments, 1957
- Temperature Effects in Gas-Free Liquid ScintillatorsIRE Transactions on Nuclear Science, 1956
- TEMPERATURE COEFFICIENTS OF SCINTILLATION DETECTORSPublished by Office of Scientific and Technical Information (OSTI) ,1956
- The application of (RCA 1P 28)-photomultiplier tubes to the detection of weak light intensitiesPhysica, 1954