The NPL ultrasound beam calibrator
- 1 March 1988
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 35 (2) , 122-139
- https://doi.org/10.1109/58.4162
Abstract
The calibrator consists of a multielement membrane hydrophone made from polyvinylidene fluoride which is mounted in a versatile test-tank and linked to a fast data acquisition and presentation system. Acoustic output parameters of both simple medical ultrasonic systems and complex automatic scanners operating in imaging modes can be determined in a straightforward manner. Designed as a comprehensive measurement system, with the calibration traceable to United Kingdom national standards and the software configured to conform with written standards, it provides a convenient and rapid method of determining the acoustic output for both manufacturers and users of medical ultrasonic equipment. A detailed description of all aspects of the beam calibrator is given. The computer operating system is described, followed by an analysis of the postprocessing calculations which are applied to the acquired waveform data for the determination of acoustical parameters. Finally, a full assessment of the sources of uncertainty in the measurements is given, together with a comparison of results obtained using a reference measurement system.<>Keywords
This publication has 12 references indexed in Scilit:
- Time-delay spectrometry for ultrasonic transducer characterisationJournal of Physics E: Scientific Instruments, 1986
- Measurement and characterisation of the acoustic output of medical ultrasonic equipment Part 2Medical & Biological Engineering & Computing, 1986
- Development of Two-Dimensional PVDF Arrays for Transmission Computed Tomography of AttenuationPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1984
- PVDF membrane hydrophone performance properties and their relevance to the measurement of the acoustic output of medical ultrasonic equipmentJournal of Physics E: Scientific Instruments, 1983
- Characteristics of a PVDF Membrane Hydrophone for Use in the Range 1-100 MHzIEEE Transactions on Sonics and Ultrasonics, 1982
- Simplified technique for the calibration and use of a miniature hydrophone in intensity measurements of pulsed ultrasound fieldsThe Journal of the Acoustical Society of America, 1981
- Piezoelectric polymer probe for ultrasonic applicationsThe Journal of the Acoustical Society of America, 1981
- On the Generation of High-Frequency Acoustic Energy with Polyvinylidene FluorideIEEE Transactions on Sonics and Ultrasonics, 1980
- PVF2 TransducersPublished by Institute of Electrical and Electronics Engineers (IEEE) ,1980
- Ultrasonic power and intensities produced by diagnostic ultrasound equipmentUltrasound in Medicine & Biology, 1978