Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement.
- 1 September 1995
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 77 (9) , 1315-1322
- https://doi.org/10.2106/00004623-199509000-00004
Abstract
Between 1980 and 1990, 1941 total hip replacements were performed with use of the Iowa femoral component fixed with cement. Twenty-seven of these patients (twenty-nine hips) had early loosening of the femoral component two to ten years (average, five years) after the operation. The average age of these patients at the time of the operation was fifty-nine years (range, forty-one to seventy-seven years). The acetabular cup had been inserted without cement in seventeen hips, and the cup had been inserted with cement in twelve. The femoral stems had a matte finish; twenty had been precoated with polymethylmethacrylate and nine had not been precoated. The pattern of loosening of the femoral stem was unique: in each hip, the loosening was initially reflected by debonding (a superolateral lucency between the cement and the prosthesis in zone 1 of Gruen et al.), and this was followed by progressive loosening at the cement-prosthesis interface with maintenance of the bone-cement interface. In twenty hips, the debonding was followed by extensive osteolysis. Twenty patients (twenty-one hips) had a revision, and one was considering a revision at the time of writing. The average time from the onset of the symptoms to the revision for the nineteen hips for which this information was available was nine months. We believe that both the geometry (a cylindrical shape distal to the proximal cobra shape) and the surface finish of the Iowa femoral component were responsible for the pattern of progressive loosening.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 10 references indexed in Scilit:
- Charnley low-friction arthroplasty of the hip: Twenty-year results with cementThe Journal of Arthroplasty, 1994
- Total hip arthroplasty with cement in patients who are less than fifty years old. A sixteen to twenty-two-year follow-up study.Journal of Bone and Joint Surgery, 1994
- Failure of the cement-bone interface. A consequence of strengthening the cement-prosthesis interface?The Journal of Bone and Joint Surgery. British volume, 1994
- Loosening and bone resorption in exeter hip arthroplasties. Review at a minimum of five yearsThe Journal of Bone and Joint Surgery. British volume, 1993
- Fracture and loosening of Charnley femoral stems. Comparison between first-generation and subsequent designsThe Journal of Bone and Joint Surgery. British volume, 1993
- The effect of improved cementing techniques on component loosening in total hip replacement. An 11-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1990
- Vacuum mixing of acrylic bone cementThe Journal of Arthroplasty, 1987
- The effect of surface preparation on metal/bone cement interfacial strengthJournal of Biomedical Materials Research, 1987
- Metal/cement interface strength in cemented stem fixationJournal of Orthopaedic Research, 1984
- Cement strain measurement surrounding loose and well‐fixed femoral component stemsJournal of Biomedical Materials Research, 1983