Setting analytical goals for random analytical error in specific clinical monitoring situations
Open Access
- 1 September 1990
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 36 (9) , 1625-1628
- https://doi.org/10.1093/clinchem/36.9.1625
Abstract
Strategies abound for the setting of analytical goals in clinical chemistry. Many, especially those more recently proposed for particular clinical situations, are concerned with tests used in diagnosis. We suggest a general theory for the setting of goals in situations that specifically involve the monitoring of individuals. Goals are calculated from the formula CVA less than [(delta c 2/2Z2)-CVB2]1/2, where CVA is the analytical imprecision (as coefficient of variation, CV); delta c is the percentage change in serial results that is considered clinically significant; Z is the Z-statistic, which depends only on the probability selected for statistical significance; and CVB is the average inherent within-subject biological variation (as CV). Examples given show applications in hematology and in monitoring diabetes mellitus, chronic renal failure, and hepatitis. The derived goals are for total random analytical error (imprecision and intermittent systematic variation), and provide objective criteria that should be achieved in practice. The effect of analytical variability on both variability in test results and the probability that a stated change can be considered significant should be calculated whether or not the goals are attained.This publication has 9 references indexed in Scilit:
- Biologic Variation of Common Hematologic Laboratory Quantities in the ElderlyAmerican Journal of Clinical Pathology, 1989
- EVALUATION OF 2 TYPES OF MEDICALLY SIGNIFICANT ERROR LIMITS AND 2 QUALITY-CONTROL PROCEDURES ON A MULTICHANNEL ANALYZER1989
- Clinically Useful Limits (CUL) Criteria as a Basis for Quality Control Including Minimal and Optimal Goals for Quality ControlAmerican Journal of Clinical Pathology, 1989
- Choosing quality-control systems to detect maximum clinically allowable analytical errors.Clinical Chemistry, 1989
- Analytical Goals for the Estimation of Non-Gaussian Reference IntervalsScandinavian Journal of Clinical and Laboratory Investigation, 1989
- Analytical goals for the acceptance of common reference intervals for laboratories throughout a geographical areaScandinavian Journal of Clinical and Laboratory Investigation, 1988
- IMPORTANCE OF TIME INTERVAL BETWEEN REPEATED MEASUREMENTS OF TOTAL OR HIGH-DENSITY-LIPOPROTEIN CHOLESTEROL WHEN ESTIMATING AN INDIVIDUALS BASE-LINE CONCENTRATIONS1987
- Medically Useful Criteria for Analytic Performance of Laboratory TestsAmerican Journal of Clinical Pathology, 1985
- A Study of the Accuracy and Precision of Clinical Chemistry Determinations in 170 Canadian LaboratoriesClinical Chemistry, 1963