Comparison of magnetic resonance volume flow rates, angiography, and carotid Dopplers. Preliminary results.
- 1 February 1994
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 25 (2) , 413-417
- https://doi.org/10.1161/01.str.25.2.413
Abstract
We compared the results of conventional angiography, carotid Doppler, and magnetic resonance angiography volume flow rates to determine the clinical utility of volume flow rate assessment of blood flow to the anterior circulation in patients with carotid occlusive disease. From 11 symptomatic patients, a total of 22 extracranial carotid arteries were studied with all three techniques. The studies were independently read, and regression analysis was used to compare the measurements. Carotid Doppler measurements of the distal extracranial carotid arteries were proportional to the inverse of the extracranial carotid volume flow rate (r = .53, R2 = 29%, P < .01), volume flow rates were proportional to the inverse of measured percent stenosis on angiography (r = .84, R2 = 71%, P < .01), and Dopplers were proportional to angiography (r = .94, R2 = 90%, P < .01). Symptomatic Doppler systolic velocity was significantly higher (P < .002), symptomatic measured stenosis was significantly higher (P < .002), and symptomatic volume flow rate was significantly lower (P < .01) than their respective asymptomatic-side values. These preliminary observations, however, may well change once a large data set, especially one in which more patients with high-grade carotid stenosis are included, is studied. Assessment of carotid volume flow rates by magnetic resonance angiography quantifies flow reduction secondary to atherosclerotic occlusive disease. The easily obtained flow data add both documentation of arterial flow characteristics related to internal carotid stenosis and information regarding the adequacy of collateral pathways.Keywords
This publication has 18 references indexed in Scilit:
- Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effectsJournal of Magnetic Resonance Imaging, 1993
- Accuracy and precision of MR velocity mapping in measurement of stenotic cross‐sectional area, flow rate, and pressure gradientJournal of Magnetic Resonance Imaging, 1993
- Magnetic Resonance Imaging of Blood Flow with a Phase Subtraction TechniqueInvestigative Radiology, 1993
- Normal Renal Blood Flow Measurement Using Phase-Contrast Cine Magnetic Resonance ImagingInvestigative Radiology, 1992
- Right and left ventricular stroke volume measurements with velocity-encoded cine MR imaging: in vitro and in vivo validation.American Journal of Roentgenology, 1991
- Three‐dimensional phase contrast angiographyMagnetic Resonance in Medicine, 1989
- MR Flow Imaging by Velocity-Compensated/Uncompensated Difference ImagesJournal of Computer Assisted Tomography, 1987
- Blood Flow Imaging by Cine Magnetic ResonanceJournal of Computer Assisted Tomography, 1986
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984
- A flow velocity zeugmatographic interlace for NMR imaging in humansMagnetic Resonance Imaging, 1982