End-tidal carbon dioxide as a measure of arterial carbon dioxide during intermittent mandatory ventilation
- 1 April 1987
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 3 (2) , 73-79
- https://doi.org/10.1007/bf00858353
Abstract
To determine if end-tidal carbon dioxide tension (PetCO2) is a clinically reliable indicator of arterial carbon dioxide tension (PaCO2) under conditions of heterogeneous tidal volumes and ventilation-perfusion inequality, we examined the expiratory gases of 25 postcardiotomy patients being weaned from ventilator support with intermittent mandatory ventilation. Using a computerized system that automatically sampled airway flow, pressure, and expired carbon dioxide tension, we were able to distinguish spontaneous ventilatory efforts from mechanical ventilatory efforts. ThePetCO2 values varied widely from breath to breath, and the arterial to end-tidal carbon dioxide tension gradient was appreciably altered during the course of several hours. About two-thirds of the time, thePetCO2 of spontaneous breaths was greater than that of ventilator breaths during the same 70-second sample period. The most accurate indicator of PaCO2 was the maximalPetCO2 value in each sample period, the correlation coefficient being 0.768 (P < 0.001) and the arterial to end-tidal gradient being 4.24 ± 4.42 mm Hg (P < 0.01 compared with all other measures). When all values from an 8-minute period were averaged, stability was significantly improved without sacrificing accuracy. We conclude that monitoring the maximalPetCO2, independent of breathing pattern, provides a clinically useful indicator of PaCO2 in postcardiotomy patients receiving intermittent mandatory ventilation.Keywords
This publication has 20 references indexed in Scilit:
- Arterial to end-tidal CO2 gradients during spontaneous breathing, intermittent positive-pressure ventilation and jet ventilationCritical Care Medicine, 1985
- ASSESSMENT OF THE HEWLETT-PACKARD HP47210A CAPNOMETERBritish Journal of Anaesthesia, 1985
- Breath-by-Breath End-Tidal Carbon Dioxide Analysis for Patients on Intermittent Mandatory VentilationPublished by Springer Nature ,1982
- Applications of respiratory mass spectrometry to intensive careAnaesthesia, 1980
- CORRELATION OF ALVEOLAR P CO 2 ESTIMATED BY INFRA-RED ANALYSIS AND ARTERIAL P CO 2 IN THE HUMAN NEONATE AND THE RABBITBritish Journal of Anaesthesia, 1977
- Expired gas monitoring by mass spectrometry in a respiratory intensive care unitCritical Care Medicine, 1976
- Mass spectrometry for innovative techniques of respirator care, ventilator weaning and differential ventilation in an intensive care unitCritical Care Medicine, 1976
- Weaning from Controlled Ventilation and Supplemental OxygenNew England Journal of Medicine, 1975
- The Arterial to End-Expiratory Carbon Dioxide Tension Gradient in Acute Pulmonary Embolism and Other Cardiopulmonary DiseasesChest, 1974
- MEASUREMENT OF INSPIRED AND EXPIRED OXYGEN AND CARBON DIOXIDEBritish Journal of Anaesthesia, 1969