Mechanistic and Morphological Origins of Ultra-High Molecular Weight Polyethylene Wear Debris in Total Joint Replacement Prostheses
- 1 September 1996
- journal article
- editorial
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 210 (3) , 141-155
- https://doi.org/10.1243/pime_proc_1996_210_407_02
Abstract
The mechanistic and morphological origins of microscopic wear debris generated from UHMWPE articular surfaces in total joint replacement prostheses are investigated in this study. It was found experimentally that the molecular chain structure at the articulating surface of UHMWPE undergoes a re-organization process due to strain accumulation caused by surface traction. This molecular re-organization process creates a fibre-like surface texture that exhibits an anisotropic behaviour similar to a unidirectionally reinforced polymer composite. This composite responds to stresses favourably if loaded along the fibre axis but unfavourably if loaded off axis. Due to the very complex multi-axial motion/loading nature at the articular surfaces in total joint replacements, the stress tensors applied to each localized asperity contact area continuously change their directions and magnitudes. These changes in the localized stress field create an off-axis loading situation at each localized contact zone with respect to the orientation of the molecular chains. Depending on the off-axis angle, failure of the molecular structure occurs in three different ways: tensile rupture at very small off-axis angles, shear rupture at intermediate off-axis angles and transverse splitting at large off-axis angles. These failure mechanisms all produce similar fibre-like wear debris. However, the failure stresses differ significantly among the three modes. According to this molecular wear theory, the preferred polymer microstructure for optimal wear resistance would be a three-dimensionally strong network connected by covalent bonds between molecular chains. For UHMWPE, a three-dimensional molecular network can be created by radiation induced cross-linking. Experiments conducted on both gamma irradiated and unirradiated UHMWPE specimens using a linear wear machine and multi-axial joint simulators confirmed the validity of the molecular wear theory.Keywords
This publication has 25 references indexed in Scilit:
- Role of cyclic plastic deformation in the wear of UHMWPE acetabular cupsJournal of Biomedical Materials Research, 1995
- Wear mechanisms of UHMWPE in total joint replacementsWear, 1995
- Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissuesJournal of Biomedical Materials Research, 1995
- Laboratory wear tests and clinical observations of the penetration of femoral heads into acetabular cups in total replacement hip joints: II: A microscopical study of the surfaces of Charnley polyethylene acetabular socketsWear, 1985
- Degradation and Wear of Ultra-High-Molecular-Weight PolyethylenePublished by ASTM International ,1985
- Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prosthesesJournal of Biomedical Materials Research, 1983
- Wear of Artificial Joint Materials IIEngineering in Medicine, 1981
- Wear mechanisms for ultrahigh molecular weight polyethylene in the total hip prosthesisJournal of Applied Polymer Science, 1979
- The appearances of wear on polyethylene—a comparison of in vivo and in vitro wear surfacesJournal of Biomedical Materials Research, 1978
- The wear of ultrahigh molecular weight polyethylene and a preliminary study of its relation to the in vivo behaviour of replacement hip jointsWear, 1976