Estimation of parallel conductance by dual-frequency conductance catheter in mice.
- 1 July 2000
- journal article
- research article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 279 (1) , H443-H450
- https://doi.org/10.1152/ajpheart.2000.279.1.h443
Abstract
The conductance catheter method has substantially enhanced the characterization of in vivo cardiovascular function in mice. Absolute volume determination requires assessment of parallel conductance ( V p) offset because of conductivity of structures external to the blood pool. Although such a determination is achievable by hypertonic saline bolus injection, this method poses potential risks to mice because of volume loading and/or contractility changes. We tested another method based on differences between blood and muscle conductances at various catheter excitation frequencies (20 vs. 2 kHz) in 33 open-chest mice. The ratio of mean frequency-dependent signal difference to V pderived by hypertonic saline injection was consistent [0.095 ± 0.01 (SD), n = 11], and both methods were strongly correlated ( r 2 = 0.97, P < 0.0001). This correlation persisted when the ratio was prospectively applied to a separate group of animals ( n = 12), with a combined regression relation of V p(DF) = 1.1 ∗ V p(Sal) − 2.5 [where V p(DF) is V p derived by the dual-frequency method and V p(Sal) is V p derived by hypertonic saline bolus injection], r 2 = 0.95, standard error of the estimate = 1.1 μl, and mean difference = 0.6 ± 1.4 μl. Varying V p(Sal) in a given animal resulted in parallel changes in V p(DF) (multiple regression r 2 = 0.92, P < 0.00001). The dominant source of V p in mice was found to be the left ventricular wall itself, since surrounding the heart in the chest with physiological saline or markedly varying right ventricular volumes had a minimal effect on the left ventricular volume signal. On the basis of V p and flow probe-derived cardiac output, end-diastolic volume and ejection fraction in normal mice were 28 ± 3 μl and 81 ± 6%, respectively, at a heart rate of 622 ± 28 min−1. Thus the dual-frequency method and independent flow signal can be used to provide absolute volumes in mice.Keywords
This publication has 23 references indexed in Scilit:
- Dilated cardiomyopathy in homozygous myosin-binding protein-C mutant miceJournal of Clinical Investigation, 1999
- Dominant-negative effect of a mutant cardiac troponin T on cardiac structure and function in transgenic mice.Journal of Clinical Investigation, 1998
- Mechanism of Acute Mechanical Benefit From VDD Pacing in Hypertrophied HeartCirculation, 1998
- Continuous measurement of left ventricular volume in rabbit, using a two-electrode catheterHeart and Vessels, 1995
- Direct recording of EDP-EDV relationship in isolated rat left ventricle: effect of diastolic crossbridge formationCardiovascular Research, 1994
- Dependence of anisotropic myocardial electrical resistivity on cardiac phase and excitation frequencyBasic Research in Cardiology, 1994
- Simultaneous conductance catheter and dimension assessment of left ventricle volume in the intact animal.Circulation, 1990
- Determination of left ventricular end-systolic pressure-volume relationships by the conductance (volume) catheter technique.Circulation, 1986
- Continuous measurement of left ventricular volume in animals and humans by conductance catheter.Circulation, 1984
- Continuous stroke volume and cardiac output from intra-ventricular dimensions obtained with impedance catheterCardiovascular Research, 1981